Siemens SENTRON PAC3120 Power Meter

The Siemens SENTRON PAC3120 is a 96 × 96 mm panel-mounted power monitoring device for three-phase electrical systems.

Looking for a cost-effective alternative? The APM-96J offers similar core measurement capabilities and additional power monitoring functions, making it worth considering for selected PAC3120 applications.

Contact us

Siemens PAC3120 vs. Blue Jay APM-96J – Technical Comparison

Similarities Between PAC3120 and APM-96J

Both meters share several core functions, making APM-96J worth evaluating for selected PAC3120 applications.

Comparison Siemens PAC3120 Blue Jay APM-96J
Product Type Multifunction Power Monitoring Device Multifunction Power Meter
Mounting 96 × 96 mm panel 96 × 96 mm panel
Measurement System Three-phase Three-phase
Current Input 1 A / 5 A CT 1 A / 5 A CT
Communication RS485 Modbus RTU RS485 Modbus RTU
Voltage Measurement Yes Yes
Current Measurement Yes Yes
Active Power Yes Yes
Reactive Power Yes Yes
Frequency Measurement Yes Yes
Active Energy Measurement Yes Yes
Digital I/O 2 DI / 2 DO Optional DI/DO

What this means: Both products support the core functions needed for three-phase electrical measurement and Modbus RTU-based monitoring. APM-96J can therefore be considered for projects where these functions are the primary requirements.

Key Differences Between PAC3120 and APM-96J

Comparison Siemens PAC3120 APM-96J
Rated Voltage 400 V L-N / 690 V L-L Direct: 18–277 V L-N; PT secondary: 100 V
Active Energy Accuracy Class 0.5 Class 0.5S
Reactive Energy Accuracy Class 2 Class 1.0
Auxiliary Power 100–250 V ±10% AC/DC 85–265 V AC/DC; optional 20–60 V DC
Harmonic Analysis Not specified in the cited datasheet Individual harmonics up to 63rd order
THD Measurement Not specified in the cited datasheet Voltage and current THD
Time-of-Use (TOU) Not listed in the cited datasheet Supported
Communication Options RS485 Modbus RTU RS485 Modbus RTU; optional Ethernet Modbus TCP / Profibus
Analog Outputs Not listed Optional 2-channel 0/4–20 mA
Digital I/O 2 DI / 2 DO Optional up to 6 DI / 4 DO

What to Check Before Replacing Siemens PAC3120?

Although APM-96J shares several measurement and communication functions with PAC3120, replacement requires checking the following details.

Replacement Consideration What You Need to Check
Voltage Input Confirm whether direct measurement or an external PT is required
CT Compatibility Select the 1 A or 5 A input according to the existing CT
Auxiliary Power Confirm that the available supply is within the APM-96J operating range
Communication Check Modbus register mapping and communication settings
Accuracy Verify that APM-96J accuracy meets the project’s requirements
Installation Confirm panel cutout, installation depth, and terminal positions
Digital I/O Check whether the existing system uses the original DI/DO functions

Important voltage consideration: If your existing PAC3120 is installed in a 690/400 V system, do not connect the 400 V line-to-neutral voltage directly to the APM-96J. An appropriately rated PT and compatible secondary voltage configuration are required.