Schneider PM5350 Power Meter

The Schneider Electric PowerLogic PM5350 is a multifunction power meter designed for electrical monitoring in commercial and industrial power distribution systems. Featuring a 96 × 96 mm panel-mounted design, it measures voltage, current, frequency, power, power factor, and energy, while providing total harmonic distortion (THD) monitoring.

With Class 0.5S active energy accuracy, RS485 Modbus communication, four digital inputs, and two relay outputs, the PM5350 supports energy monitoring, equipment status monitoring, and remote electrical data collection. Its compact 44 mm installation depth makes it suitable for space-constrained electrical panels and switchboards.

Contact us

Feature of Schneider PM5350

Class 0.5S Energy Measurement
Provides Class 0.5S active energy accuracy according to IEC 62053-22, supporting accurate electricity consumption monitoring and energy cost allocation.

Power Quality Monitoring
Measures total harmonic distortion (THD), helping users identify harmonic distortion and monitor electrical system conditions.

RS485 Modbus Communication
Supports Modbus RTU and ASCII communication for integration with PLC, SCADA, and energy management systems.

Digital Inputs and Relay Outputs
Four digital inputs and two relay outputs support external status monitoring, alarm signaling, and equipment control.

Compact Panel Installation
The 96 × 96 mm flush-mounted design and 44 mm installation depth help save space in electrical distribution panels.

Specification of Schneider PM5350

Parameters Specifications
Brand Schneider Electric
Product Series PowerLogic PM5000
Model PM5350
Order Number METSEPM5350
Product Type Power Meter
Mounting Flush Mount
Front Dimensions 96 × 96 mm
Installation Depth 44 mm
Network Configuration 1P+N / 3P / 3P+N
Rated Current Input 1 A / 5 A
Voltage Input L-L 20–480 V AC, CAT III
Voltage Input L-N 20–277 V AC, CAT III
Frequency 45–70 Hz
Active Energy Accuracy Class 0.5S, IEC 62053-22
Current Accuracy ±0.3%
Voltage Accuracy ±0.3%
Frequency Accuracy ±0.05%
Power Factor Accuracy ±0.005
Sampling Rate 32 samples/cycle
Harmonic Monitoring THD
Digital Inputs 4
Relay Outputs 2
Communication RS485
Protocols Modbus RTU / Modbus ASCII
Auxiliary Supply 85–265 V AC / 100–300 V DC
Display 6-line monochrome graphic LCD
Memory Non-volatile memory for parameters and alarms

Replace your PM5350 monitoring with APM-96Q

Selection point Schneider PM5350 APM-96Q What this means for replacement
Nominal CT input 1 A / 5 A 1 A / 5 A options Order the installed CT secondary; verify measurement and overload limits.
Active-energy standard IEC 62053-22 Class 0.5S, with stated current conditions Published active energy 0.2; equivalent standard evidence unverified Request evidence covering the accuracy standard required by the project.
Independent circuits Multi Circuit mode: up to three loads Equivalent independent-circuit mode unverified Include a defined multi-circuit solution if the original mode is used.
Voltage measurement 20-400 V L-N; 20-690 V L-L including specified overrange 100 / 220 / 380 V ordering options Select voltage rating and connection; include VTs where required.
Control power 85-265 V AC; 100-300 V DC 85-265 V AC/DC standard; 48 V DC or 380 V AC customization published Specify the power version for the actual site supply; confirm its full operating range.
I/O electrical types 4 voltage-status DI; 2 relay DO up to 8 A resistive at 250 V AC under stated conditions Optional up to 6 dry DI / 4 relay DO; 5 A at 250 V AC listed Select I/O counts and adapt electrical interfaces and contact ratings.
Alarm and energy workflow Alarm history; THD/thd/TDD; 64-bit energy values described 50 SOE entries; selected APM data types and records Test event history, energy types and every required TDD or alarm point.
Opening and depth Installation opening 92 +0.8 x 92 +0.8 mm; 44 mm rear depth in guide Manual opening 91 x 91 mm; depth drawing 74 mm Check the actual opening, fixing and cable clearance.