Schneider Electric PowerLogic PM800 Series Power Meters

The Schneider Electric PowerLogic PM800 Series includes the PM810, PM820, and PM850 multifunction power meters, designed for electrical measurement and monitoring in industrial and commercial power distribution systems.

All three models provide three-phase electrical measurement, power and energy monitoring, THD measurement, RS485 Modbus communication, and standard digital input and KY pulse output functions. Their main differences are in data logging, individual harmonic measurement, and waveform capture capabilities.

Contact us

Alternative options for Schneider PM800 series power meter

With the PM800 Series now discontinued, we offers the APM-96J and APM-96Q as alternative options for selected applications. The APM-96J is suitable for PM810 and PM820 replacement projects, while the APM-96Q provides more advanced power quality monitoring functions for applications previously using PM850.

Original Model Main Function Recommended Blue Jay Alternative
PM810 Basic power monitoring; optional data logging APM-96J
PM820 Individual voltage and current harmonic measurement APM-96J
PM850 Advanced monitoring with waveform capture APM-96Q

Schneider PM810, PM820 and PM850 Technical Specifications

Parameters PM810 PM820 PM850
Product Series PowerLogic PM800 PowerLogic PM800 PowerLogic PM800
Mounting Panel Mount Panel Mount Panel Mount
Front Dimensions 96 × 96 mm 96 × 96 mm 96 × 96 mm
Nominal CT Input 5 A AC 5 A AC 5 A AC
Current Input Range 5 mA–10 A AC 5 mA–10 A AC 5 mA–10 A AC
Voltage Input 0–600 V L-L / 347 V L-N 0–600 V L-L / 347 V L-N 0–600 V L-L / 347 V L-N
Frequency 45–67 Hz 45–67 Hz 45–67 Hz
Active Energy Accuracy Class 0.5S Class 0.5S Class 0.5S
Reactive Energy Accuracy Class 2 Class 2 Class 2
Harmonic Measurement THD THD + Individual Harmonics THD + Individual Harmonics
Communication RS485 Modbus RTU RS485 Modbus RTU RS485 Modbus RTU
Digital Input 1 standard 1 standard 1 standard
KY Pulse Output 1 standard 1 standard 1 standard
Auxiliary Power 115–415 V AC / 125–250 V DC 115–415 V AC / 125–250 V DC 115–415 V AC / 125–250 V DC

Key Differences Between PM810, PM820 and PM850

Parameters PM810 PM820 PM850
Individual Harmonic Readings Not listed as standard Yes Yes
Waveform Capture No No Yes
Data Logging 80 KB with PM810LOG option 80 KB 800 KB
Main Differentiation Basic monitoring Individual harmonic analysis Waveform capture and advanced logging