Specification
Parameter | Values | Note |
Rated input | ±50A, ±100A, ±200A, ±300A, ±400A, ±500A, ±600A | Standard input |
Input measurement range | ±60A, ±120A, ±240A, ±360A, ±480A, ±600A, ±720A | Default is 1.2 times of rated input |
Rated output | 2.5V±0.625V | Standard output |
Accuracy | 1% | I = IPN, I = 0 ~ ±IPN |
Linearity | 1% | – |
Supply voltage | +5V | Supply voltage range = ±5% |
Current consumption | ≤16mA | Reference will be subject to the measured |
Load impedance | ≥10KΩ | Collection port impedance while lower voltage affect accuracy |
Zero offset voltage | ≤±15mV | TA = 25°C |
Response time | ≤5 μs | Reference will be subject to the measured |
Weight | 84g | Reference will be subject to the measured |
Operation temperature | -10 ~ +70°C | – |
Storage temperature | -25 ~ +70°C | – |
Band width | DC ~ 25KHz | Factory test according to DC |
Dielectric strength | 2.5KV 50Hz 1min | – |
Installation diagram