Feature of ABB M4M 30
Advanced Power Quality Analysis
THD measurement, individual harmonics up to the 40th order, and voltage/current unbalance monitoring.
Neutral Current Measurement
Measures neutral current to help evaluate electrical loading and unbalanced conditions.
Data Logging and Alarm Monitoring
Supports recording of electrical trends, alarms, and system events for monitoring and troubleshooting.
Multiple Communication Options
Depending on the ordered version, supports Modbus RTU, Modbus TCP/IP, BACnet/IP, and Profibus DP-V0.
Technical Specifications
| Parameters | ABB M4M 30 |
|---|---|
| Product Type | Power Quality Analyzer |
| Mounting | Panel Mount |
| Front Dimensions | 96 × 96 mm |
| Overall Depth | 85 mm |
| Voltage Measurement | Yes |
| Current Measurement | Yes |
| Frequency | Yes |
| Active Power | Yes |
| Reactive Power | Yes |
| Apparent Power | Yes |
| Active Energy | Yes |
| Reactive Energy | Yes |
| Apparent Energy | Yes |
| Active Energy Accuracy | Class 0.5S, IEC 62053-22 |
| THD Measurement | Voltage and Current |
| Individual Harmonics | Up to 40th order |
| Voltage / Current Unbalance | Yes |
| Neutral Current | Measured |
| Four-Quadrant Energy | Yes |
| Tariff Measurement | Yes |
| Data Recording | Yes |
| Alarm Functions | 15 configurable alarms |
| CT Input | 1 A / 5 A |
| Auxiliary Power | 100–230 V AC/DC ±15% |
| Communication | Modbus RTU / Modbus TCP/IP / BACnet/IP / Profibus DP-V0, version dependent |
| Digital I/O | Optional, depending on version |
| Display | Color graphic touchscreen |
| Front Protection | IP51 |
| Terminal Protection | IP20 |
Cost-effective Alternative Solution for ABB M4M 30
| Selection point | ABB M4M 30 | APM-96Q | Replacement implication |
| Electrical monitoring | V, I, P, Q, S, PF and energy | Panel electrical and energy measurements | Define required values and acceptance tests. |
| Harmonics | Individual harmonics through 40th | Through 127th in manual V1.14 | Check accuracy, channels and reporting format. |
| Active energy | 0.5S at 5 A; cited manual derates 1 A to Class 1 | Published 0.2 without S | 0.2 is not evidence of 0.5S certification equivalence. |
| Current channels | Four CT inputs; separate Rogowski version | Conventional 1 A / 5 A; fourth channel unverified | No confirmed direct reuse of ABB R4M coils. |
| Voltage / supply | Up to 400 V L-N; supply 48–240 V AC/DC ±15% | Published 18–277 V L-N; standard supply 85–265 V AC/DC | 690 V direct and low auxiliary feeds need engineering. |
| Network interface | RTU, TCP, Profibus or BACnet by version; dual-port Ethernet | RTU; optional TCP; other equivalent interfaces unverified | Obtain option-specific interface evidence. |
| Recording and I/O | Trend logs, logic alarms and programmable I/O | SOE / alarms; optional logging and I/O | Match retention, timing, input type and outputs. |
| Installation / climate | 92 mm opening; −25 to +70°C | 91 +0.8/0 mm opening; −10 to +55°C | Check fixing, enclosure and thermal conditions. |