Circutor CVM-C10-ITF-485-ICT2 Power Analyzer

The Circutor CVM-C10-ITF-485-ICT2 is a 96 × 96 mm panel-mounted power analyzer designed for three-phase and single-phase electrical monitoring. It supports four-quadrant measurement, energy recording, and harmonic analysis up to the 31st order.

With RS485 Modbus RTU and BACnet communication, two digital inputs, two relay outputs, and two transistor outputs, the CVM-C10 supports electrical monitoring and integration with industrial automation and energy management systems.

Circutor lists the CVM-C11-ITF-IN-485-ICT2 as its replacement model, making it important for users to check availability and compatibility when maintaining existing CVM-C10 installations.

Contact us

Key Features

  • 96 × 96 mm panel mounting.
  • Four-quadrant energy measurement.
  • Three-phase and single-phase measurement configurations.
  • Individual harmonic measurement up to 31st order.
  • RS485 Modbus RTU and BACnet.
  • Two digital inputs.
  • Two relay outputs.
  • Two transistor outputs.
  • Energy recording.

Technical Specifications

Parameters CVM-C10-ITF-485-ICT2
Mounting Panel Mount
Front Dimensions 96 × 96 mm
CT Input 1 A / 5 A
Measurement Three-phase / Single-phase, configuration dependent
Energy Measurement Four Quadrants
Harmonics Up to 31st
Communication RS485
Protocols Modbus RTU / BACnet
Digital Inputs 2
Relay Outputs 2
Transistor Outputs 2
Auxiliary Supply Confirm exact version
Product Status Availability to be confirmed

Cost-effective alternative solution for CVM-C10-ITF-485-ICT2

Selection point Circutor CVM-C10-ITF-485-ICT2 APM-96J Replacement implication
Identification M55911; three current channels; 1 A / 5 A Three-phase 1 A / 5 A options Comparison is for this ITF version. [S15; MJ; J]
Harmonics Through 31st Through 63rd in selected manual Verify the required per-phase results. [S15; MJ; J]
Communications RS-485 RTU / BACnet RTU; BACnet equivalent unverified Use a new profile or an engineered gateway. [S15; MJ; J]
I/O 2 DI, 2 transistor and 2 relay outputs DI, relay and pulse options Match type, timing and load individually. [S15; MJ; J]
Supply / voltage 95–240 V AC ±10%; DC range differs; 300 V L-N nominal input 85–265 V AC/DC standard; published 18–277 V L-N Check full measurement and supply envelopes. [S15; MJ; J]
Select the offered inputs Verify installed CT or sensor output and measuring voltage 1 A / 5 A CT; select voltage rating Check polarity, ratio, burden and continuous ratings. [MJ; J]
Select the offered supply Verify nameplate and actual supply extremes 85–265 V AC/DC standard; low-voltage option requires confirmation Supply rating is separate from measuring voltage. [MJ; J]