Janitza UMG 801 Modular Power Analyzer

The Janitza UMG 801 is a modular power analyzer designed for centralized monitoring of multiple electrical circuits in industrial facilities and critical power distribution systems.

Its modular architecture supports expansion to up to 92 current measurement channels, allowing users to monitor multiple feeders and loads through one measurement platform. With Class 0.2S active energy accuracy, harmonic analysis up to the 127th order for voltage, 4 GB internal memory, and IEC 61000-4-30 Class S power quality monitoring, the UMG 801 is suitable for advanced energy management and power quality applications.

Contact us

Key Features

  • Modular expansion up to 92 current measurement channels.
  • Eight integrated 1 A / 5 A current measurement inputs.
  • Four multifunction channels for current, temperature, or residual current measurement.
  • Voltage harmonics up to 127th order.
  • Current harmonics up to 63rd order.
  • IEC 61000-4-30 Class S.
  • Class 0.2S active energy accuracy.
  • 4 GB memory.
  • RS485, dual Ethernet, and USB.
  • Modbus RTU, Modbus TCP/IP, and OPC UA.

Technical Specifications

Parameters UMG 801
Product Type Modular Power Analyzer
Mounting DIN Rail / Modular
Supply Voltage 24 V DC PELV
Current Inputs 8 × 1 A / 5 A
Expandable Current Channels Up to 92
Multifunction Channels 4
Voltage System 3-wire / 4-wire
Active Energy Accuracy Class 0.2S
Voltage Accuracy 0.2%
Current Accuracy 0.2%
Voltage Harmonics Up to 127th
Current Harmonics Up to 63rd
Power Quality IEC 61000-4-30 Class S
Digital Inputs 4
Digital Outputs 4
Memory 4 GB
Interfaces RS485 / 2 × Ethernet / USB
Protocols Modbus RTU / Modbus TCP/IP / OPC UA
Sampling Rate 51.2 kHz (Voltage) / 25.6 kHz (Current)

Janitza UMG 801 Monitoring Alternatives with APM-96Q

Selection point Janitza UMG 801 APM-96Q Replacement implication and source
Current channels 8 conventional current channels in base device Conventional three-phase monitoring One APM cannot cover all original channels.
PQ and energy Class S; 0.2S at 5 A Class S unverified; energy published 0.2 No standards equivalence established.
Harmonics V through 127th; I through 63rd Published harmonics through 127th Channel coverage and performance still need verification.
Storage and power 4 GB; 24 V DC PELV Optional logging; nonstandard low supply to confirm Specify retention and correctly rated power conversion.
Services Ethernet, USB, OPC UA and gateway functions RTU; optional TCP External services needed where mandatory.
Select the offered inputs Verify installed CT or sensor output and measuring voltage 1 A / 5 A CT; select voltage rating Check polarity, ratio, burden and continuous ratings.
Select the offered supply Verify nameplate and actual supply extremes 85–265 V AC/DC standard; custom supply requires confirmation Supply rating is separate from measuring voltage.