Feature of Schneider PM5350
Class 0.5S Energy Measurement
Provides Class 0.5S active energy accuracy according to IEC 62053-22, supporting accurate electricity consumption monitoring and energy cost allocation.
Power Quality Monitoring
Measures total harmonic distortion (THD), helping users identify harmonic distortion and monitor electrical system conditions.
RS485 Modbus Communication
Supports Modbus RTU and ASCII communication for integration with PLC, SCADA, and energy management systems.
Digital Inputs and Relay Outputs
Four digital inputs and two relay outputs support external status monitoring, alarm signaling, and equipment control.
Compact Panel Installation
The 96 × 96 mm flush-mounted design and 44 mm installation depth help save space in electrical distribution panels.
Specification of Schneider PM5350
| Parameters | Specifications |
|---|---|
| Brand | Schneider Electric |
| Product Series | PowerLogic PM5000 |
| Model | PM5350 |
| Order Number | METSEPM5350 |
| Product Type | Power Meter |
| Mounting | Flush Mount |
| Front Dimensions | 96 × 96 mm |
| Installation Depth | 44 mm |
| Network Configuration | 1P+N / 3P / 3P+N |
| Rated Current Input | 1 A / 5 A |
| Voltage Input L-L | 20–480 V AC, CAT III |
| Voltage Input L-N | 20–277 V AC, CAT III |
| Frequency | 45–70 Hz |
| Active Energy Accuracy | Class 0.5S, IEC 62053-22 |
| Current Accuracy | ±0.3% |
| Voltage Accuracy | ±0.3% |
| Frequency Accuracy | ±0.05% |
| Power Factor Accuracy | ±0.005 |
| Sampling Rate | 32 samples/cycle |
| Harmonic Monitoring | THD |
| Digital Inputs | 4 |
| Relay Outputs | 2 |
| Communication | RS485 |
| Protocols | Modbus RTU / Modbus ASCII |
| Auxiliary Supply | 85–265 V AC / 100–300 V DC |
| Display | 6-line monochrome graphic LCD |
| Memory | Non-volatile memory for parameters and alarms |
Replace your PM5350 monitoring with APM-96Q
| Selection point | Schneider PM5350 | APM-96Q | What this means for replacement |
| Nominal CT input | 1 A / 5 A | 1 A / 5 A options | Order the installed CT secondary; verify measurement and overload limits. |
| Active-energy standard | IEC 62053-22 Class 0.5S, with stated current conditions | Published active energy 0.2; equivalent standard evidence unverified | Request evidence covering the accuracy standard required by the project. |
| Independent circuits | Multi Circuit mode: up to three loads | Equivalent independent-circuit mode unverified | Include a defined multi-circuit solution if the original mode is used. |
| Voltage measurement | 20-400 V L-N; 20-690 V L-L including specified overrange | 100 / 220 / 380 V ordering options | Select voltage rating and connection; include VTs where required. |
| Control power | 85-265 V AC; 100-300 V DC | 85-265 V AC/DC standard; 48 V DC or 380 V AC customization published | Specify the power version for the actual site supply; confirm its full operating range. |
| I/O electrical types | 4 voltage-status DI; 2 relay DO up to 8 A resistive at 250 V AC under stated conditions | Optional up to 6 dry DI / 4 relay DO; 5 A at 250 V AC listed | Select I/O counts and adapt electrical interfaces and contact ratings. |
| Alarm and energy workflow | Alarm history; THD/thd/TDD; 64-bit energy values described | 50 SOE entries; selected APM data types and records | Test event history, energy types and every required TDD or alarm point. |
| Opening and depth | Installation opening 92 +0.8 x 92 +0.8 mm; 44 mm rear depth in guide | Manual opening 91 x 91 mm; depth drawing 74 mm | Check the actual opening, fixing and cable clearance. |