ETCR3200 Ground Resistance Meter Double Clamp Multifunction Earth Resistance Tester

ETCR3200 Double Clamp Earth Resistance Meter Multifunction Soil Resistivity Ground Resistance Tester Grounding voltage 0.0V~100.0V and AC voltage measurement 0.00mA~600A

Contact us

Feature of ETCR3200

  • ETCR3200 Double Clamp Grounding Resistance Tester is specially designed for the measurement of earth resistance, soil resistivity, earth voltage, leakage current of the grounding line, AC, DC resistance.
  • ETCR3200 Double Clamp Grounding Resistance Tester is composed of the host machine, monitoring software, testing wires, auxiliary ground pillars, communication wires and others.
  • The large LCD of host machine is with blue backlight and bar graph indicating that can be seen clearly.
  • ETCR3200 Double Clamp Earth Resistance Meter can flexibly and precisely measure the value of grounding resistance in every complicated situation like single point grounding, and grounding mesh; it does not need to disconnect any parallel connection pole when measuring parallel-grounding, and massively improve the convenience when measuring.
  • At the same time it can store 2000 sets of data, fulfilling historical inquiry and online real-time monitoring through monitoring software, dynamic display, and alarm indicator, auto-shut down and with the functions like historical data access, reading, preservation, report forms, printing and so on.

Specification of ETCR3200

Power Supply DC 9V Alkaline dry cell LR14 1.5V*6PCS, continues standby 300 hours
LCD Size 124mm x 67mm(with backlight)
Range Selection measurement method :0.01Ω – 3000Ω | Double clamp measurement method :0.01Ω – 100Ω | Soil Resistivity :0.01Ωm – 9000KΩ | DC Resistance:0.01Ω – 30.00kΩ | Earth Voltage:0.1V -100.0V | AC Current:0.01mA -600A
Resolution Resistance:0.01Ω | Soil Resistivity :0.01Ωm | Current:0.01mA | Voltage:0.1V
Max Accuracy ±2%rdg±3dgt
Data Storage 2000 groups
Data Upload RS232 interface, storage data can be uploaded to computer, saved or printed.
Automatic Shut Down Automatically shut down after 15 minutes start up
Power Consumption Turn on the backlight: 45mA Max | Turn off the backlight : 25mA Max | Measurement: 100mA Max(Backlight shut off)
Working Temperature & Humidity -10℃-40℃, below 80%rh
Storage temperature & humidity -20℃-60℃, below 70%rh
Clamp Caliber Φ50mm
Measuring Method 2/3/4 pole measurement method: Change-pole method, measurement current 20mA Max | Selection measurement method: Change-pole method, measurement current 20mA Max | Soil Resistivity: 4-pole measurement (Wenner method) | AC current: Mutual inductance method(clamp) | Earth Voltage: Average rectification(between P(S)-ES)
Test Frequency 128Hz/111Hz/105Hz/94Hz(AFC)
Data Model Average value,maximum,minimum value
line resistance check Automatic calibration
Measuring Rate AC current: about 0.5 times/second | Earth Voltage: about 0.5 times/second | Earth resistance,soil resistivity: about 5 seconds/time
Measuring Times Over 5000 times (Short-circuit test, interval time should be at least 30seconds)
Short-circuit Test Current AC 20mA max
Open-circuit Test Voltage AC 40V max
Test Voltage Wave Sine wave
Electrode Distance Range 1m-100m
Line Voltage Measurement below AC 600V
Data Hold Data hold function: “HOLD” symbol display
Data Access Data read function: “READ” symbol display
Overflow Display Exceed measuring range overflow function: “OL” symbol display
Auxiliary Grounding Test With auxiliary grounding resistance test function, 0.00KΩ-30kΩ(100R+rC<50kΩ, 100R+rP<50kΩ)
Interference Test Automatic identification of interference signals, “NOISE” symbol indication when the interference voltage is higher than 5V
Alarm Function Measuring value exceeds alarm setting value, will “Toot-toot-toot” alarm hint
Battery Voltage While battery voltage decreases to around 7.5V, will display battery voltage low symbol“ ”, and reminding to replace the battery
Overload Protection Measure earth resistance: between each interfaces of E-P、E-E- C, AC 280V/3 seconds
Insulation Resistance Over 20MΩ(between circuit and outside shell is 500V)
Withstand Voltage AC 3700V/rms. (Between circuit and outside shell)
Electromagnetic Features IEC61010- 4-3,Wireless frequency electromagnetic field ≤1 V/m
Safety Standard IEC61010-1(CAT Ⅲ 300V、CAT IV 150V、Pollution 2) | IEC61010-031 | IEC61557-1(Earth resistance) | IEC61557-5(Soil resistivity) | JJG 366-2004(Grounding resistance meter)
Weight 1653g
Meter Dimension 215mm(L)×178mm(W)×83mm(H)