SATEC PM130 PLUS Multifunction Power Meter

The SATEC PM130 PLUS is a multifunction three-phase power meter designed for utility substations, industrial facilities, and SCADA applications. It measures voltage, current, power, energy, frequency, power factor, and electrical system unbalance, supporting comprehensive electrical monitoring.

A key feature of the PM130 PLUS is its ability to measure both AC and DC electrical systems. In addition to conventional 1 A and 5 A current inputs, it supports specialized 40 mA HACS inputs and DC current measurement through an external shunt. With RS485 communication, optional Ethernet and Profibus, and flexible digital and analog I/O, the PM130 PLUS is suitable for a wide range of power monitoring applications.

Contact us

Key Features

  • Three-phase multifunction power measurement.
  • AC and DC energy metering.
  • 1 A / 5 A CT inputs.
  • Optional 40 mA HACS inputs.
  • DC measurement through external shunt.
  • Harmonic analysis up to 40th order.
  • Class 0.5 / 0.5S active energy accuracy.
  • Optional Class 0.2S calibration.
  • RS485, optional Ethernet and Profibus.
  • Up to 16 digital and analog I/O.

Technical Specifications

Parameters PM130 PLUS
Product Type Multifunction Power Meter
Mounting Panel Mount
Current Input 1 A / 5 A / 40 mA HACS
DC Measurement Via external shunt
Voltage Input 15–828 V AC L-L
Frequency 25 / 50 / 60 / 400 Hz
Active Energy Accuracy Class 0.5 / 0.5S
Optional Accuracy Class 0.2S calibration
Harmonics Up to 40th
THD / TDD Yes
K-Factor Yes
Communication RS485; optional Ethernet / Wi-Fi / Profibus
Protocols Modbus RTU / DNP3.0 / IEC 60870-5-101/104
Digital / Analog I/O Up to 16, configuration dependent
Display 7-Segment LED with Load Bar

Cost-effctive Alternative Solution for SATEC PM130 PLUS

Selection point Original SATEC APM-96J Replacement implication and source
Family functions P basic; E adds energy; EH adds harmonics through 40th Electrical parameters, energy and 63rd harmonics Match the actual model, region and firmware.
Energy 0.5S per IEC published Published 0.5S Verify standard and operating conditions.
Application envelope AC; DC shunt capability; 25/50/60/400 Hz options Conventional mains-frequency AC No DC or 400 Hz substitution established.
Protocols Modbus, DNP3, IEC 60870 options RTU; TCP / Profibus options Utility protocol support requires separate evidence or services.
Expansion Multiple I/O modules; up to 16 I/O Configured optional I/O Inventory modules and map electrical signal types.
Select the offered inputs Verify installed CT or sensor output and measuring voltage 1 A / 5 A CT; select voltage rating Check polarity, ratio, burden and continuous ratings.
Select the offered supply Verify nameplate and actual supply extremes 85–265 V AC/DC standard; low-voltage option requires confirmation Supply rating is separate from measuring voltage.