Feature of Remote Overhead Line Fault Indicator
- Short Circuit: Indicated by a red mechanical flag and three ultra-bright blinking LEDs.
- Earth-fault: Indicated by a red mechanical flag and three ultra-bright blinking LEDs.
- Low Battery Warning: Indicated by red mechanical flag
- Parameter Adjusted: The parameters can be read and adjusted by the bidirectional wireless tool.
- Remote Transmission: DCU can transmit data to the SCADA system.
- Power Supply: The indicator can take power from overhead lines, with a lithium battery as backup. The DCU can take power from solar energy with lithium battery backup.
Specification of Remote Overhead Line Fault Indicator
JYZ-HW V2.0 Overhead Line Remote Fault Indicator Features and Options
Subject | Value |
Permanent Fault | Indication of permanent fault by three red ultra-bright blinking LEDs. |
Instantaneous Fault | Indication of instantaneous fault by three green ultra-bright blinking LEDs. |
Earth-fault | Indication of earth-fault by red and green ultra-bright LEDs blinking alternately. |
Low Battery Warning | Indication of Low battery alarm by three yellow ultra-bright blinking LEDs. |
Parameter Adjusted | The parameters can be read and adjusted by bidirectional wireless tools. |
Remote Transmission | DCU can transmit data to a remote SCADA system. |
Power Supply | The indicator can take power from overhead lines, with lithium battery backup. The DCU can take power from solar energy with lithium battery backup. |
General Data
Subject | Value |
Short-circuit Trip Current (Phase to Phase) | Adjustable, 1A step, 150A default |
Earth-fault Voltage Drop (Phase to Ground) | Adjustable: 1% step, 30% default |
Earth-fault Response Delay | Adjustable: 1 second step, 30s default |
Indication Unit Reset | 1 manual by magnet 2 communications by wireless tools or DCU (optional) 3-time reset: adjustable, 1-second step, 24h default 4 Auto delay reset after repower, 1 second step, 30s default |
Protection Class | IP68 |
Internal Type Test | According to IEEE495-2007 |
Operation Temperature Range | -40~+70℃ |
Power Supply | Lithium battery type AA 3.6V / 2.7Ah, replaceable |
Battery Life | Approx. 10 years |
Weight | <1kg |
Dimensions | Diameter: 93mm Height: 170mm |
Accuracy | 0A~300A ±3A 300A~800A ±1% |
Cable Diameter Ranges | 6mm~42mm |
Blinking Frequency | 20 per minute, adjustable |
Maximum Operating Voltage | <= 38KV |
Current Withstand | 31.5KA/2s |
Communication | 433MHz from indicators to DCU 2G/3G/4G from DCU to SCADA |