NITV 1000 2000 3000 Series Pneumatic Pressure Regulator

Series ITV electro-pneumatic and electronic vacuum regulators control air/vacuum pressure steplessly in proportion to an electric signal. The units are compact, lightweight, and include an easy-to-read LED display. Input signals can be analog current or voltage, 4 or 16 point presets, or a range of communication protocols including CC-Link, DeviceNet™, PROFIBUS, RS-232C or I/O-Link. EtherNet/IP™, and PROFINET are available as well. See the separate configurators on this site. Monitor output is available as an analog or switch signal. ITV regulators are IP65 equivalent.

Contact us
Category:

Feature

 

• High Precision provides highly accurate air pressure regulation in a small package

• High Sensitivity senses output pressure deviations to within 1/8 inch water column pressure

• Wide Pressure Ranges pressure ranges up to 120 psig (8 bar)

• Compact

 

Specification

 

Model

NITV101□Note8) NITV103□Note8) NITV105□ Note8)
NITV201□ NITV203□ NITV205□
NITV301□ NITV303□ NITV305□
Minimum supply pressure Set pressure +0.1 MPa
Maximum supply pressure 0.2MPa 1.0MPa
Set pressure range Note 1) 0.005 to 0.1 MPa 0.005 to 0.5 MPa 0.005 to 0.9 MPa
 

Power supply

Voltage 24 VDC ± 10%, 12 to 15 VDC
Current consumption Power supply voltage 24 VDC type: 0.12 A or less Note 9)

Power supply voltage 12 to 15 VDC type: 0.18 A or less

 

Input signaNote 9)

Current typeNote 2) 4 to 20 mA DC, 0 to 20 mA DC (Sink type)
Voltage type 0 to 5 VDC, 0 to 10 VDC
Preset input 4 points (Negative common), 16 points (No common polarity)
Input impedance Current type 250 Ω or less Note 6)
Voltage type Approx. 6.5 KΩ
Digital input Power supply voltage 24 VDC type: Approx. 4.7 KΩ Power supply voltage 12 VDC type: Approx. 2.0 KΩ
 

 

Output signal output (monitor output)

 

Analog out

1 to 5 VDC (Output impedance: Approx. 1 kΩ)

4 to 20 mA DC (Sink type) (Output impedance: 250 Ω or less) Output accuracy ± 6% F.S. or less

Switch out NPN open collector output: Max. 30 V, 80 mA PNP open collector output: Max. 80 mA
Linearity ± 1% F.S. or less
Hysteresis 0.5% F.S. or less
Repeatability ± 0.5% F.S. or less
Sensitivity 0.2% F.S. or less
Temperature characteristics ± 0.12% F.S./°C or less
Output pressure display Note 4) Accuracy ± 2% F.S. ± 1 digit or less
Minimum unit Mpa: 0.001, kgf/cm2: 0.01, bar: 0.01, psi: 0.1 Note 5) , kPa: 1
Ambient and fluid temperature 0 to 50°C (No condensation)
Enclosure Ip65
 

Weight Note 10)

NITV10□□ Approx. 250 g (without options)
NITV20□□ Approx. 350 g (without options)
NITV30□□ Approx. 645 g (without options)