Features
- Available in open delayed, open in-phase, and closed transition types
- Automatic and non-automatic modes of operation
- Includes an interlocked, double-throw power switch driven by a robust solenoid operating mechanism
- Service entrance rated option available with Eaton’s Arcflash Reduction Maintenance System to reduce the incident energy levels for downstream equipment during periods of maintenance
- Indoor and outdoor enclosure types
- Listed to UL 1008 and CSA 22.2 No. 178, Seismic certified
- Integrated Cam-Lok receptacle power panel that serves as a docking station for quick connection of a portable or temporary generator
Applications
- Contactor and circuit breaker construction
- Open (time delayed, in-phase, load voltage decay) and closed transition switching
- Bypass-isolation functionality
- Automatic transfer switch (ATS) controller and remote annunciator Integral overcurrent protection
Specification
Contactor | Molded Case | Power Frame | Bypass Isolation | Contactor | |
Application Standard
configuration |
Yes | Yes | Yes | ||
Bypass isolation | Yes | Yes | |||
Service entrance 1 | Yes | Yes | Yes | Yes | Yes |
Overcurrent protection | Yes | Yes | Yes | Yes | Yes |
ArcFlash Reduction Maintenance System (ARMS) |
Yes |
Yes |
Yes |
Yes |
Yes |
Integral generator docking station (Cam-Lok) | Yes | Yes | Yes | Yes | Yes |
Integral load bank docking station (Cam-Lok) | Yes | Yes | Yes | Yes | |
Electrical Amperage | 40 – 3000 A | 40 – 1000 A | 200 – 5000 A | 100 – 3000 A | 200 – 5000 A |
Voltage | up to 600 Vac | up to 600 Vac | up to 600 Vac | up to 600 Vac | up to 600 Vac |
Frequency | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz |
AC power system |
single and three-phase | single and three-phase | single and three-phase | single and three-phase | single and three-phase |
Wire configuration | 3 or 4-wire | 3 or 4-wire | 3 or 4-wire | 3 or 4-wire | 3 or 4-wire |
Power poles | 2, 3, 4 | 2, 3, 4 | 2, 3, 4 | 2, 3, 4 | 2, 3, 4 |
Transition Open | Yes | Yes | Yes | Yes | Yes |
Open (time delayed) | Yes | Yes | Yes | Yes | Yes |
Open (load voltage decay) | Yes | Yes | Yes | Yes | Yes |
Open (in-phase) | Yes | Yes | Yes | Yes | |
Closed (with fallback to open option) |
Yes |
Yes |
Yes |
Yes |
|
Operation Automatic | Yes | Yes | Yes | Yes | Yes |
Non-Automatic | Yes | Yes | Yes | Yes | Yes |
Manual | Yes 2 | Yes | Yes | Yes 2 | Yes |
Neutral Solid
configuration |
Yes | Yes | Yes | Yes | Yes |
Switched | Yes | Yes | Yes | Yes | Yes |
Enclosure type NEMA | 1, 3R, 4X, 12 | 1, 3R, 4X, 12 | 1, 3R, 3RX | 1, 3R, 4X, 12 | 1, 3R, 3RX |
Product UL 1008 listed
standard CSA C22.2 No. 178.1 certified |
Yes
Yes |
Yes
Yes |
Yes
Yes |
Yes
Yes |
Yes
Yes |