Janitza UMG 96-PQ-L Power Quality Analyzer

The Janitza UMG 96-PQ-L is an advanced power quality analyzer designed for detailed electrical monitoring and power quality assessment in industrial and commercial power distribution systems.

It provides Class 0.2S active energy accuracy, harmonic analysis up to the 65th order, and IEC 61000-4-30 Class S power quality measurement capabilities on applicable configurations. With RS485 and Ethernet communication, 64 MB of internal memory, and configurable digital I/O, it supports power quality analysis, disturbance monitoring, and long-term energy data recording.

Contact us

Key Features

  • Harmonic analysis up to the 65th order.
  • IEC 61000-4-30 Class S capabilities, depending on variant and activation.
  • Class 0.2S active energy accuracy.
  • 64 MB data memory.
  • RS485 and Ethernet.
  • Modbus RTU and Modbus TCP/IP.
  • Three digital inputs and three digital/pulse outputs.
  • Flicker, interharmonics, and voltage disturbance monitoring.
  • Integrated web server and event recording.

Technical Specifications

Parameters UMG 96-PQ-L
Mounting Panel Mount
Front Dimensions 96 × 96 mm
Auxiliary Supply AC 90–277 V AC / 24–90 V AC versions
Auxiliary Supply DC 90–250 V DC / 24–90 V DC versions
Current Input 1 A / 5 A CT
Voltage System TN / TT; IT on selected variants
Active Energy Accuracy Class 0.2S
Harmonics Up to 65th
Power Quality Standard IEC 61000-4-30 Class S, variant dependent
Memory 64 MB
Digital Inputs 3
Digital / Pulse Outputs 3
Analog Outputs 1
Communication RS485 / Ethernet
Protocols Modbus RTU / Modbus TCP/IP
Display Color Graphic Display

Alternative solution for UMG 96-PQ-L

Selection point Janitza UMG 96-PQ-L APM-96Q Replacement implication
Harmonics Through 65th Through 127th in V1.14 Count does not establish matching PQ performance.
Energy accuracy 0.2S at 5 A Published 0.2 without S Standard equivalence is unverified.
PQ option Class S available; flicker / interharmonics Some PQ functions advertised IEC 61000-4-30 Class S equivalence is not evidenced.
Memory 64 MB; event and long-term partitions Optional 128 MB logging; SOE Capacity alone does not prove retention or event timing.
Expansion Neutral, RCM, temperature, Ethernet gateway Options depend on exact order Module, gateway and fourth-input equivalence unverified.
Select the offered inputs Verify installed CT or sensor output and measuring voltage 1 A / 5 A CT; select voltage rating Check polarity, ratio, burden and continuous ratings.
Select the offered supply Verify nameplate and actual supply extremes 85–265 V AC/DC standard; custom supply requires confirmation Supply rating is separate from measuring voltage.