Feature of Schneider PM700
Comprehensive Electrical Measurement
Measures voltage, current, active power, reactive power, apparent power, energy, frequency, and power factor across single-phase and three-phase electrical systems.
Power Quality Monitoring
Monitors voltage and current total harmonic distortion (THD), helping users identify harmonic distortion in electrical installations.
Demand and Min/Max Monitoring
Records current and power demand, along with minimum and maximum instantaneous readings, for electrical system monitoring and analysis.
Easy-to-Read Display
Features a large, backlit LCD with integrated bar graphs, displaying multiple electrical measurements for convenient on-site monitoring.
Compact Panel Installation
The 96 × 96 mm panel-mounted design extends only 50 mm behind the mounting surface, helping save space inside switchboards.
Specification of Schneider PM700
General Specifications
| Parameters | PM700 | PM710 | PM750 |
|---|---|---|---|
| Product Type | Power Meter | Power Meter | Power Meter |
| Product Series | PowerLogic PM700 | PowerLogic PM700 | PowerLogic PM700 |
| Mounting | Panel Mount | Panel Mount | Panel Mount |
| Front Dimensions | 96 × 96 mm | 96 × 96 mm | 96 × 96 mm |
| Installation Depth | 50 mm | 50 mm | 50 mm |
| Display | Backlit LCD | Backlit LCD | Backlit LCD |
| Measurement System | 1P / 2P / 3P | 1P / 2P / 3P | 1P / 2P / 3P |
| Sampling Rate | 32 samples/cycle | 32 samples/cycle | 32 samples/cycle |
Measurement and Accuracy
| Parameters | PM700 | PM710 | PM750 |
|---|---|---|---|
| Voltage Measurement | Yes | Yes | Yes |
| Current Measurement | Yes | Yes | Yes |
| Active Power | Yes | Yes | Yes |
| Reactive Power | Yes | Yes | Yes |
| Apparent Power | Yes | Yes | Yes |
| Active Energy | Yes | Yes | Yes |
| Reactive Energy | Yes | Yes | Yes |
| Frequency | Yes | Yes | Yes |
| Power Factor | Yes | Yes | Yes |
| Voltage THD | Yes | Yes | Yes |
| Current THD | Yes | Yes | Yes |
| Current Demand | Yes | Yes | Yes |
| Power Demand | Yes | Yes | Yes |
| Min/Max Readings | Yes | Yes | Yes |
| Active Energy Accuracy | Class 1 | Class 1 | Class 0.5S |
| Reactive Energy Accuracy | Class 2 | Class 2 | Class 2 |
Communication and Digital I/O
| Parameters | PM700 | PM710 | PM750 |
|---|---|---|---|
| RS485 | No | Yes | Yes |
| Modbus RTU | No | Yes | Yes |
| Digital Inputs | No | No | 2 |
| Digital Outputs | No | No | 1 |
| Alarm Functions | No | No | Yes |
| Pulse Outputs | No | No | Selectable output function |
Replacement solution for Schneider PM700, PM710, & PM750
| Original Model | Recommended Alternative | Replacement Positioning |
|---|---|---|
| PM700 | APM-96Z | Alternative for basic electrical measurement |
| PM710 | APM-96Z | Alternative with communication capabilities |
| PM750 | APM-96J | Alternative for high-accuracy metering and digital I/O applications |