Circutor CVM-E3-MINI Three-Phase DIN Rail Power Analyzer

The Circutor CVM-E3-MINI is a compact three-phase power analyzer designed for electrical measurement and energy monitoring in low-voltage distribution systems. Its three-module DIN rail mounting design helps save installation space in electrical panels.

It supports four-quadrant measurement, voltage and current monitoring, active and reactive power measurement, and harmonic analysis up to the 31st order. Depending on the selected version, it offers RS485 Modbus RTU or BACnet communication, digital inputs, and transistor pulse outputs for integration with energy management systems.

Contact us

Key Features

  • Compact three-module DIN rail installation.
  • Three-phase balanced and unbalanced measurement.
  • Four-quadrant power measurement.
  • Voltage and current THD and harmonics up to 31st order.
  • 1 A / 5 A CT versions.
  • Optional 250 mA or Rogowski sensor versions.
  • RS485 Modbus RTU or BACnet versions.
  • One digital input and one transistor output on selected versions.

Technical Specifications

Parameters CVM-E3-MINI-ITF-485-IC
Mounting DIN Rail
Width 3 DIN Modules
Power Supply 207–253 V AC
Voltage Input 300 V L-N / 520 V L-L
CT Input 1 A / 5 A
Frequency 45–65 Hz
Voltage Accuracy 0.5% ± 1 digit
Current Accuracy 0.5% ± 1 digit
Active Power Accuracy 0.5% ± 2 digits
Active Energy Accuracy Class 1 / Class 0.5, current dependent
Reactive Energy Accuracy Class 2
Harmonics Up to 31st
Communication RS485
Protocols Modbus RTU / BACnet
Digital Inputs 1
Transistor Outputs 1
Protection IP31; front IP40

Cost-effectice Alternative Solution for CVM-E3-MINI

Selection point Circutor CVM-E3-MINI APM-4MJ Replacement implication
Compared version M56414 ITF-485-IC; CT 1 A / 5 A 1 A / 5 A to order MC 250 mA and WiEth versions require separate assessment.
Communication RTU and BACnet via RS-485 Modbus RTU BACnet is not established as a native equivalent.
Harmonics Through 31st Through 63rd in selected manual Check output accuracy and available points.
Energy Class 1 below 0.1 In / Class 0.5 above, as published Manual states 0.5S Assess low-load behaviour and applicable standards.
I/O 1 digital input and 1 NPN transistor output One pulse output or DO; equivalent DI unverified Confirm the input duty before selecting hardware.
Power M56414 listed 207–253 V AC 85–265 V AC/DC standard Select from actual supply and required approvals.
Select the offered inputs Verify installed CT or sensor output and measuring voltage 1 A / 5 A / 100 mA options; select voltage rating Check polarity, ratio, burden and continuous ratings.
Select the offered supply Verify nameplate and actual supply extremes 85–265 V AC/DC standard; custom supply requires confirmation Supply rating is separate from measuring voltage.