Features
- High isolation voltage, the isolation voltage between input and output can reach 2500VDC;
- Stable and reliable performance: use electromagnetic isolation technology;
- Low temperature drift;
- The output port and power port can withstand 2KV surge impact;
- High accuracy, better than 0.2;
- easy installation: using rail installation, in line with international standards.
Applications
- Computer field data acquisition
- Industrial control
- PLC control and other automatic control system.
Specification
Test condition | Auxiliary power: +12 V
Room temperature: 25℃ |
Input range | 0~500VDC |
Output | 0~5VDC, 4~20mA, 0~10VDC, 0~20mA |
Power supply | 12VDC, 15VDC, 24VDC, 220VAC optional |
Accuracy | 0.2 |
Load capacity | ≥2KΩ (voltage output);
≤250Ω (current output) |
Temperature drift | ≤300ppm/°C |
Isolation voltage | 2500 V DC |
Response time | ≤300 mS |
Rated power consumption | voltage output≤400mW,
current output (4~20mA) ≤800mW |
Output ripple | ≤10mV |
Frequency range | 45~65Hz up to 5K
(please specify when ordering) |
Surge immunity | Power supply port three 2000V (L-N/ 2Ω/ integrated wave),
Analog I/O port three 2000V (L-N / 40Ω / integrated wave) |
Impulse immunity | None |
Input overload capacity | 2 times the rated input value, 1 second 10 times |
Operating temperature | -10 ~ 60°C; |
Storage temperature | -40 ~+70°C |