Features
- Optional functions including AI, AO, PWM output.
- Each channel of the MAX 32 channels IO has a maximum switching current of 5A and a maximum switching power of 1385VA/150W, with high-speed magnetic isolation, strong anti-interference, stable performance and high reliability;
- The switch input uses photoelectric isolation, which can be connected to dry and wet nodes such as key switch, relay output, magnetic/proximity switch, infrared switch, active signal input, etc. For active input signal, it can be powered separately from the main power supply and effectively isolated;
- Abundant status indicators, including switch output status indicator, switch input status indicator, communication indicator, power indicator, etc.;
- One-key initialization: press Init-SET, then power on to reset, and after 5 seconds, the system will restore to factory settings;
- With standard isolation RS232, RS485 interface, customizable network port 100M/10M TCPIP interface, CAN interface;
- Built-in TTL communication port, which is used to expand communication modules such as GSM/ GRPS/ CDMA/ ZigBee/ Wi-Fi/ Bluetooth;
- Various relay output modes can be set through the protocol;
- Built-in alarm buzzer, which can remotely control the alarm and remind the scene;
- Built-in 8-bit DIP switch, various functions can be flexibly set according to the following table:
DIP switch bit | Functions | Details |
No.8 | Linkage setting | Set ON, there is DI and corresponding DO;
The output is linked with the input |
No.7 | Communication loss reset | Set ON, the communication is lost for 2 seconds, and the output of all relays is turned off |
No.6 | Device address settings | Set ON, use software to set the device address;
Set OFF, the switch sets the device address mode; The 5th to 1st bits of the switch correspond to the set device address (No. 1-31, coded according to 8421) |
No.5–1 | Switches 5-4 OFF, 1 ON | The communication address is 1 |
Switches 5-3/1 OFF, 2 ON | The communication address is 2 | |
Switches 5-3 OFF, 1/2 ON | The communication address is 3 | |
Switches 5-4/1-2 OFF, 3 ON | The communication address is 4 | |
Switches 5-4/2 OFF, 3/1 ON | The communication address is 5 | |
Switches 5-4/1 OFF, 3/2 ON | The communication address is 6 | |
Switches 5-4 OFF, 3/2/1 ON | The communication address is 7 | |
Switches 5/3-1 OFF, 4 ON | The communication address is 8 | |
Omit… | (Defined by 8421 code combination in hexadecimal) | |
Switches 5-1 ON | The communication address is 31 |
Specification
Digital input/output | |
Input type | Passive node (dry contact) @withstand voltage ≥24VDC |
Active node (wet contact) | |
Counting pulse frequency | 1 to 40kHz
Higher frequency range can be customized (Counting function needs to be customized) |
Relay output | 32 channels of relay outputs
(NO contact, contact capacity AC250V*5A/DC30V*5A) |
Communication | |
RS485 interface | Connect up to 32 terminals
(256 terminals for the enhanced version) |
Transmission distance: 1200 meters | |
± 15KV ESD protection | |
RS232 interface | RS232 serial port is usually equipped
(Crossover cable is required when using RS232) |
Transmission distance: 10 meters | |
± 15KV ESD protection | |
RS485/232 | 7 communication rates and 6 formats are optional
(MODBUS protocol 06 func. definition table for details) |
CAN interface | Parameters can be customized |
TCP IP network port | Max. transmission distance: 100 meters |
10/100Mbps | |
MDI/MDIX crossover directly and automatically switch | |
TCP Server/TCP Client/UDP Server/UDP Client working modes and port parameters can be freely set | |
Communication protocol | Standard Modbus-RTU protocol |
Standard Modbus-TCP protocol | |
CAN interface protocol | |
Other parameters | |
Isolation withstand voltage | 1500V DC |
Max. power consumption | <17W |
Auxiliary power supply | 24V/1A DC(21-26V), 12V/2A DC(10-15V) |
Operating temperature | -20℃~+60℃ |
Installation | Rail or screw mounting |
Models
ZH-YX3232-14N | 32 channels of switch input
32 channels of relay output 24V power supply RS485 interface |
ZH-YX3232-34N | 32 channels of switch input
32 channels of relay output 24V power supply Network interface |
ZH-YX3232-12N | 32 channels of switch input
32 channels of relay output 12V power supply RS485 interface |
ZH-YX3232-34N | 32 channels of switch input
32 channels of relay output 12V power supply Network interface |