Features
- Now Available for 2″ to 12″ line sizes!
- External AC or DC power versions, with battery backup
- Minimal straight pipe
- Meter mounted rate/total indicator
- Pulse and 4-20mA output standard
- Additional optional output: HART/4-20mA, Modbus, or Digital
- Optional datalogger
- Use in water & wastewater treatment, municipalities, pump skids, pump stations, packaged plants, filtration systems, reclaimed water, hydraulic fracturing
- NSF-61 approved, IP68 rated
- iMAG-4700 and iMAG4700r models also available
Specifications
Pipe Sizes | 2”, 3”, 4”, 6”, 8”, 10”, 12” | ||||||
Flanges | 150 lb. ANSI Pattern | ||||||
Pressure | 150 psi (10.3 bar) line pressure | ||||||
Temperature | Operating | 10˚ to 140˚ F (-12˚ to 60˚ C) | |||||
Humidity | Humidity 0-90% RH to 60˚ C, altitude 2000m | ||||||
Storage | -40˚ to 158˚ F (-40˚ to 70˚ C) | ||||||
Accuracy | ±0.75% of reading on iMAG 4700p and 4700r (±1.0% iMAG 4700), ±0.025% of full-scale flow from low flow cutoff to maxi. flow rate of 10 m/sec | ||||||
Low Flow Cutoff | 0.5% of maximum flow rate | ||||||
Material | Body (2”-12”) | Welded steel, epoxy-coated | |||||
Liner (2”, 3” & 8”) | Polyurethane/Noryl® | ||||||
Liner (4”, 6”, 10” & 12”) | Santoprene flange/Polypropylene liner body | ||||||
Electronics Housing | Powder-coated diecast aluminum | ||||||
Electrodes | 316 stainless steel standard/ Hastelloy optional | ||||||
Display | Type | 128×64 dot-matrix LCD | |||||
Digits | 5 Digit Rate | 8 Digit Total | |||||
Units
Please Note: All iMAG meters are factory set for gallons per minute (GPM) rate and gallons total. If other units are required, they can be set in the field. |
Rate Volume Units | Rate Time Units | Total Volume Units | ||||
Gallons Liters
Barrels(42 gal) Cubic Feet Cubic Meters |
Million Gallons2 Mega Liters2 Imperial Gallons Million Imperial
Gallons2 |
Second Minute Hour Day | Gallons Gallons x 10
Gallons x 100 Gallons x 1000 Million Gallons Liters Kilo Liters Mega Liters |
Barrels (42 gal) Cubic Meters Cubic Meters x 1000 Cubic Feet
Cubic Feet x 100 Cubic Feet x 1000 Second Foot Day Million Cubic Feet |
Acre Feet
Acre Inches Imperial Gallons Imperial Gallons x 1000 Million Imperial Gallons Fluid Ounces |
||
Bidirectional1 | Forward Total, Reverse Total, Net Total, Batch Forward Total, Batch Reverse Total3 | ||||||
Power4 | DC Power | 9-36 Vdc @ 250 mA max, 30 mA average supplied from secondary non-hazardous live source | |||||
Battery Backup
(Not for use as primary power) |
DC powered units: One lithium 7.2V ‘D’ size battery pack, replaceable. AC powered units: One 9V alkaline battery, replaceable. | ||||||
AC Power | 100-240Vac, 50/60Hz, 0.12A (iMAG 4700r and 4700p only) Overvoltage category II | ||||||
Battery | One lithium 7.2V ‘D’ size battery pack, replaceable. (iMAG 4700 only) | ||||||
Scaled Pulse Output | Signal | Current sinking pulse, isolated, 36 Vdc at 10 mA max | |||||
Pulse Rates | User-scalable from 0.1 to 99,999.9 volume units/pulse. Pulse width is one-half of pulse period with minimum pulse width of 2.5 ms, 200 pulses/sec max. For battery option meters, pulse width varies with frequency, 150 pulses/sec max. | ||||||
Options | 4-20mA Current Loop | Isolated, passive, 24Vdc, 650 Ω maximum current loop | |||||
High Speed Digital | Isolated, open collector, 24 Vdc (iMAG4700p only) | ||||||
Serial Communications | Isolated, asynchronous serial RS485, Modbus® RTU protocol | ||||||
Sensus Smart Output | Connects to Sensus SmartPoint | ||||||
Cable | Power/Output Cable | 20ft (6m) standard length polyurethane jacketed cable—for power and outputs (lengths up to 200’ available). | |||||
Remote Display Cable | 20ft (6m) standard length polyurethane jacketed cable—for connection between meter and remote display (lengths up to 200’ available). (iMAG 4700r) | ||||||
Conductivity | >20 microSiemens/cm | ||||||
Empty Pipe Detection | Hardware/software, conductivity-based | ||||||
Regulatory | (EN 61326), 2”-12” certified to NSF/ANSI standard 61 60°C (140°F), CSA/CUS | ||||||
Environmental | NEMA 6P, CSA 6P, IEC 60925 IP68 (10ft (3m) depth, continuously) Pollution degree 4, stability fixed/built in |