FMG900-Series Electromagnetic Flow Meter

The complete lack of moving parts of this insertion Electromagnetic Flow Meter is the source of its reliability. There is no rotor to stop turning in dirty water and there are no bearings to wear out. Brass and stainless steel models withstand a variety of temperature, pressure, and chemical conditions. Reverse flow output and immersibility are optional. A rapidly reversing magnetic field is produced in the lower housing. As the fluid moves through this field, a voltage is generated that is measured and translated into a frequency signal proportional to flow rate.

Contact us

Feature

  • Durable
  • Adjustable Depth
  • Hot-Tap Available
  • Brass or Stainless Steel

Specifications

  • Power: 12 to 24 Vdc, 250 mA
  • Flow Range: 0.28 to 20 ft/sec (0.08 to 6.09 m/sec) Connection Size
  • Standard Units: 1½ NPT male, hot tap models, 2 NPT male
  • Ambient Temperature: -17 to 72°C (0 to 160°F)
  • Fluid Temperature: 0 to 93°C (32 to 200°F)
  • Maximum Pressure: 13.8 bar (200 psi)
  • Minimum Conductivity: 20 microSiemens/cm
  • Shaft and Fitting: 316 SS or brass (depending on model)
  • Electrodes: Hastelloy®
  • Electrode Cap: PVDF
  • Housing: Cast powder-coated aluminum
  • Valve: Bronze or SS (depending on model)
  • O-Ring: EPDM
  • Accuracy: ±1% of full scale
  • Output: Square wave pulse, opto isolated, 550 Hz @ 20 ft/sec 6 mA max, 30 Vdc forward flow standard (reverse flow optional)
  • Empty Pipe: Defaults to zero flow
Flow Range LPM (GPM)
Pipe Size Min Flow Max Flow
3 23 (6) 1666 (440)
4 42 (11) 2964 (783)
6 95 (25) 6670 (1762)
8 167 (44) 11,860 (3133)
10 261 (69) 18,530 (4895)
12 375 (99) 26,687 (7050)
14 507 (134) 36,325 (9596)
16 662 (175) 47,443 (12,533)
18 840 (222) 60,050 (15,863)
20 1,037 (274) 74,134 (19,584)
24 1,495 (395) 160,749 (28,200)
30 2,336 (617) 166,800 (44,064)
36 3,361 (888) 240,192 (63,452)