Specification of MCR-SL-CAC- 5-I Contact Current Transducer
Maximum power dissipation for nominal condition | 1.2 W |
Protective circuit | Surge protection; 35 V suppressor diode |
Step response (10-90%) | ≤ 300 ms |
200 ms | |
Maximum temperature coefficient | < 0.02 %/K |
Temperature coefficient, typical | < 0.015 %/K |
Maximum transmission error | ≤ 0.5 % (of nominal range value under nominal conditions) |
Reverse polarity protection | yes |
Rated insulation voltage | 300 V AC (to earth) |
Electrical isolation Input/output | |
Test voltage | 4 kV AC (50 Hz, 60 s) |
Electrical isolation Output/supply | |
Test voltage | 2 kV AC (50 Hz, 60 s) |
Supply | |
Nominal supply voltage | 24 V DC -20 % … +25 % |
Supply voltage range | 19.2 V DC … 30 V DC |
Max. current consumption | < 32 mA (at UB=24 V DC, IOUT=20 mA) |
Power consumption | < 0.9 W (at UB=24 V DC, IOUT=20 mA) |