Features of Schneider LC1D09P7
- long service life, able to withstand high voltage and high current loads.
- Elevated sensitivity and rapid response time can guarantee precise circuit functioning.
- It is easy to install, has a straightforward operation, and can be adjusted to fit different circuit needs.
- It is lightweight, compact, and requires minimal room.
- It can increase the stability of the circuit and endure high, low, and humid environments.
- Effective sealing can stop extraneous objects from getting into the
- High power, appropriate for high-power circuit control.
- Minimal vibration, minimal noise, steady operation.
- Possesses strong durability
Applications of Schneider LC1D09P7
- Frequently employed in large-scale air conditioning system control.
- Lighting system to operate the light switch.
- Used in refrigeration systems for compressor control.
- The motor can perform standard start-stop and reverse operations under motor control.
- Used to regulate the connecting and disconnecting of capacitors in power capacitor banks
- Utilized in industrial manufacturing lines’ automation control
Specification of Contactor LC1D09P7
Motor power kW | 2.2 kW 220…230 V AC 50/60 Hz AC-3) 4 kW 380…400 V AC 50/60 Hz AC-3) 4 kW 415…440 V AC 50/60 Hz AC-3) 5.5 kW 500 V AC 50/60 Hz AC-3) 5.5 kW 660…690 V AC 50/60 Hz AC-3) 2.2 kW 400 V AC 50/60 Hz AC-4) 2.2 kW 220…230 V AC 50/60 Hz AC-3e) 4 kW 380…400 V AC 50/60 Hz AC-3e) 4 kW 415…440 V AC 50/60 Hz AC-3e) 5.5 kW 500 V AC 50/60 Hz AC-3e) 5.5 kW 660…690 V AC 50/60 Hz AC-3e) |
---|---|
Maximum Horse Power Rating | 1 hp 230/240 V at AC 50/60 Hz for 1 phase 2 hp 200/208 V at AC 50/60 Hz for 3 phase 2 hp 230/240 V at AC 50/60 Hz for 3 phase 5 hp 460/480 V at AC 50/60 Hz for 3 phase 7.5 hp 575/600 V at AC 50/60 Hz for 3 phase 0.33 hp 115 V at AC 50/60 Hz for 1 phase |
Compatibility code | LC1D |
Pole contact composition | 3 NO |
Contact compatibility | M2 |
Protective cover | With |
[Ith] conventional free air thermal current | 25 A 140 °F (60 °C) power circuit 10 A 140 °F (60 °C) signalling circuit |
Irms rated making capacity | 250 A 440 V power circuit IEC 60947 140 A AC signalling circuit IEC 60947-5-1 250 A DC signalling circuit IEC 60947-5-1 |
Rated breaking capacity | 250 A 440 V power circuit IEC 60947 |
[Icw] rated short-time withstand current | 105 A 104 °F (40 °C) – 10 s power circuit 210 A 104 °F (40 °C) – 1 s power circuit 30 A 104 °F (40 °C) – 10 min power circuit 61 A 104 °F (40 °C) – 1 min power circuit 100 A – 1 s signalling circuit 120 A – 500 ms signalling circuit 140 A – 100 ms signalling circuit |
Associated fuse rating | 10 A gG signalling circuit IEC 60947-5-1 25 A gG <= 690 V type 1 power circuit 20 A gG <= 690 V type 2 power circuit |
Average impedance | 2.5 mOhm – Ith 25 A 50 Hz power circuit |
Power dissipation per pole | 1.56 W AC-1 0.2 W AC-3 0.2 W AC-3e |
[Ui] rated insulation voltage | Power circuit 690 V IEC 60947-4-1 Power circuit 600 V CSA Power circuit 600 V UL Signalling circuit 690 V IEC 60947-1 Signalling circuit 600 V CSA Signalling circuit 600 V UL |
Overvoltage category | III |
Pollution degree | 3 |
[Uimp] rated impulse withstand voltage | 6 kV IEC 60947 |
Safety reliability level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
Mechanical durability | 15 Mcycles |
Electrical durability | 0.6 Mcycles 25 A AC-1 <= 440 V 2 Mcycles 9 A AC-3 <= 440 V 2 Mcycles 9 A AC-3e <= 440 V |
Control circuit type | AC 50/60 Hz standard |
Coil technology | Without built-in suppressor module |
Control circuit voltage limits | 0.3…0.6 Uc -40…158 °F (-40…70 °C) drop-out AC 50/60 Hz 0.8…1.1 Uc -40…140 °F (-40…60 °C) operational AC 50 Hz 0.85…1.1 Uc -40…140 °F (-40…60 °C) operational AC 60 Hz 1…1.1 Uc 140…158 °F (60…70 °C) operational AC 50/60 Hz |
Inrush power in VA | 70 VA 60 Hz 0.75 68 °F (20 °C)) 70 VA 50 Hz 0.75 68 °F (20 °C)) |
Hold-in power consumption in VA | 7.5 VA 60 Hz 0.3 68 °F (20 °C)) 7 VA 50 Hz 0.3 68 °F (20 °C)) |
Heat dissipation | 2…3 W 50/60 Hz |
Operating time | 12…22 ms closing 4…19 ms opening |
Maximum operating rate | 3600 cyc/h 140 °F (60 °C) |
Connections – terminals | Power circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²) flexible without cable end Power circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²) flexible without cable end Power circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²) flexible with cable end Power circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²) flexible with cable end Power circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²) solid without cable end Power circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²) solid without cable end Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²) flexible without cable end Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²) flexible without cable end Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²) flexible with cable end Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²) flexible with cable end Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²) solid without cable end Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²) solid without cable end |
Tightening torque | Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2 Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2 Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals pozidriv No 2 Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals pozidriv No 2 |
auxiliary contact composition | 1 NO + 1 NC |
Auxiliary contacts type | Mechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1 |
Signalling circuit frequency | 25…400 Hz |
Minimum switching voltage | 17 V signalling circuit |
Minimum switching current | 5 mA signalling circuit |
Insulation resistance | > 10 MOhm signalling circuit |
Non-overlap time | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact |
Mounting Support | Rail Plate |