GF Signet 2537 Paddlewheel Flow Meter

GF Signet 2537 Paddlewheel Flow Meter is a Low flow capable flow meter, as low as 0.3ft/s with choice of output, and can be installed into 0.5 to 8-inch pipes.

Contact us

The GF Signet 2537 paddlewheel flow meter builds upon the trusted legacy of its predecessors, offering several improvements:

  • Advanced Functionality:
    • Multiple output options for flexibility: flow switch, pulse divider, digital (S³L), or 4-20mA.
    • Low flow, low power consumption, and high resolution for precise measurement.
    • On-site configuration through a user-friendly interface for easy setup.
  • Simple Installation:
    • Uses common fittings compatible with Signet 515 and 2536 sensors.
    • Fits pipes ranging from DN15 to DN200 (0.5 to 8 inches).
  • Durable Construction: Available in Polypropylene and PVDF materials for compatibility with various chemicals.
  • Versatile Applications: Ideal for chemical processing, water/wastewater monitoring, and scrubber control.

Feature of GF Signet 2537 Paddlewheel Flow Meter

  • Digital (S3L) and 4 to 20 mA outputs (Multi-function)
  • Allows up to six connections to the Signet 8900 Controller
  • Low flow capabilities down to 0.1 m/s (0.3 ft/s)
  • Polypropylene or PVDF sensor bodies
  • Polypropylene or PVDF retaining nuts
  • Installs into pipe sizes DN15 to DN200 (1/2to 8 in.)
  • Test certificate included for -X0, -X1
  • Low-power and high-resolution options

Application of GF Signet 2537 Paddlewheel Flow Meter

  • Process flow monitoring
  • Pump protection
  • Pure water production
  • Filtration systems
  • Chemical production
  • Reverse osmosis
  • Demineralization / regeneration
  • Fume scrubbers
  • Cooling towers
  • Proportional metering pump

Specification of GF Signet 2537 Paddlewheel Flow Meter

Feature Value
Operating Range 0.1 m/s to 6 m/s
Pipe Size Range DN15 to DN200
Linearity ±1% of max. range @ 25 °C (77 °F)
Repeatability ±0.5% of max. range @ 25 °C [77 °F)
System Response 100 ms update rate nominal
Sensor Body Glass-filled PP (black) or PVDF (natural)
O-rings FPM (std) optional EPR (EPDM) or FFPM
Rotor Pin Titanium, Hastelloy-C or PVDF; optional Ceramic, Tantalum or Stainless Steel
Rotor Black PVDF or Natural PVDF; optional ETFE, with or w/o carbon fiber reinforced PTFE sleeve for rotor pin
Multi With Dry-Contact Relay
With Solid-State Relay
Digital (SL)
4 to 20 mA
Maximum Pulse Rate 300 Hz
Maximum Pulse Width 50 ms
Minimum Pulse Rate 0.5 Hz
Compatible with PLC, PC or similar equipment Yes
Compatible with customer supplied metering pump Yes
Digital [SL] Version 5 VDC nominal, regulated, 3 mA max current
Type
Max. Cable Length
Compatible with Model Signet 8900 controller
4 to 20 mA Version 12 to 32 VDC nominal, ±10%, regulated, 21 mA max current
Loop Accuracy
Loop Resolution
Temp. Drift
Power Supply Rejection
Max. Cable
Maximum Loop Resistance
Load Impedance
Reverse Polarity and Short Circuit Protected Up to 40 V, 1 hour
Over-voltage Protection > 40 VDC over 1 hour
Storage Temperature -10 °C to 75 °C
Operating Temperature 0°C to 65 °C
Relative Humidity 0 to 90%, non-condensing
Flow Sensor/ PP 12.5 bar @ 20 °C
Retaining Nut 1.7 bar @ 85 °C
PVDF 14 bar @ 20 °C
1.7 bar @ 85 °C
Operating Temperature PP
PVDF
Environmental Enclosure NEMA 4X/IP65