| product function |
Phase monitoring relay |
| display version LED |
No |
| design of the display |
LCD |
| insulation voltage for overvoltage category III according to IEC 60664 |
|
| ● with degree of pollution 3 rated value |
690 V |
| degree of pollution |
3 |
| type of voltage |
|
| ● for monitoring |
AC |
| ● of the control supply voltage |
AC |
| surge voltage resistance rated value |
6 kV |
| protection class IP |
IP20 |
| shock resistance according to IEC 60068-2-27 |
sinusoidal half-wave 15g / 11 ms |
| vibration resistance according to IEC 60068-2-6 |
1 … 6 Hz: 15 mm, 6 … 500 Hz: 2g |
| mechanical service life (switching cycles) typical |
10 000 000 |
| electrical endurance (switching cycles) at AC-15 at 230 V typical |
100 000 |
| thermal current of the switching element with contacts maximum |
5 A |
| reference code according to IEC 81346-2 |
K |
| relative repeat accuracy |
1 % |
| Substance Prohibitance (Date) |
05/01/2012 |
| Product Function |
| product function |
|
| ● undervoltage detection |
Yes |
| ● overvoltage detection |
Yes |
| ● phase sequence recognition |
Yes |
| ● phase failure detection |
Yes |
| ● asymmetry detection |
Yes |
| ● overvoltage detection 3 phase |
Yes |
| ● undervoltage detection 3 phases |
Yes |
| ● voltage window recognition 3 phase |
Yes |
| ● adjustable open/closed-circuit current principle |
No |
| ● auto-RESET |
Yes |
| Control circuit/ Control |
| control supply voltage at AC |
|
| ● at 50 Hz rated value |
160 … 690 V |
| ● at 60 Hz rated value |
160 … 690 V |
| operating range factor control supply voltage rated value at AC at 50 Hz |
|
| ● initial value |
1 |
| ● full-scale value |
1 |
| operating range factor control supply voltage rated value at AC at 60 Hz |
|
| ● initial value |
1 |
| ● full-scale value |
1 |
| Measuring circuit |
| measurable voltage at AC |
690 … 160 V |
| adjustable response delay time |
|
| ● with lower or upper limit violation |
0.1 … 20 s |
| accuracy of digital display |
+/-1 digit |
| Precision |
| relative metering precision |
5 % |
| Auxiliary circuit |
| number of NC contacts delayed switching |
0 |
| number of NO contacts delayed switching |
0 |
| number of CO contacts delayed switching |
2 |
| operating frequency with 3RT2 contactor maximum |
5 000 1/h |
| Main circuit |
| number of poles for main current circuit |
3 |
| ampacity of the output relay at AC-15 |
|
| ● at 250 V at 50/60 Hz |
3 A |
| ● at 400 V at 50/60 Hz |
3 A |
| ampacity of the output relay at DC-13 |
|
| ● at 24 V |
1 A |
| ● at 125 V |
0.2 A |
| ● at 250 V |
0.1 A |
| operational current at 17 V minimum |
5 mA |
| continuous current of the DIAZED fuse link of the output relay |
4 A |
| Electromagnetic compatibility |
| conducted interference |
|
| ● due to burst according to IEC 61000-4-4 |
2 kV |
| ● due to conductor-earth surge according to IEC 61000-4-5 |
2 kV |
| ● due to conductor-conductor surge according to IEC 61000-4-5 |
1 kV |
| field-based interference according to IEC 61000-4-3 |
10 V/m |
| electrostatic discharge according to IEC 61000-4-2 |
6 kV contact discharge / 8 kV air discharge |