Features
- Standard, 3m Cable
- negative pressure (-101.3 to 0.0kPa)
- standard pressure (0 to 100.0kPa, 0 to 1,000kPa)
- compound pressure (-101.3 to 100.0kPa)
- Compact design: W11.8×H29.3×L24.8mm (including pressure port)
- Analog output: Voltage (1-5VDC)
- Power supply: 12-24VDC ±10%
Applications
- Industrial OEM Equipment
- Hydraulic systems
- Compressor control
- HVAC/R equipment
- Industrial engines
- Tank level
Specification
| General Specifications | |||||
| Pressure type | Gauge pressure | ||||
| Negative pressure | Standard pressure | Compound pressure | |||
| Model | Voltage output | PSS-V01V-R1/8 | PSS-01V-R1/8 | PSS-1V-R1/8 | PSS-C01V-R1/8 | 
| Current output | PSS-V01A-R1/8 | PSS-01A-R1/8 | PSS-1A-R1/8 | PSS-C01A-R1/8 | |
| Rated pressure range | 0.0 to -101.3kPa | 0.0 to 100.0kPa | 0 to 1,000kPa | -101.3 to 100.0kPa | |
| Analog output range | 5.0 to -101.3kPa | -5.0 to 110.0kPa | -50 to 1,100kPa | -101.3 to 110.0kPa | |
| Max. pressure range | 2 times of rated pressure | 2 times of rated pressure | 1.5 times of rated pressure | 2 times of rated pressure | |
| Applied fluid | Air, non-corrosive gas | ||||
| Power supply | 12-24VDC ±10% (ripple P-P: Max. 10%) | ||||
| Current consumption | Voltage output type: Max. 15mA, Current output type: – | ||||
| Effect by power supply | Max. ±0.3% F.S. | ||||
| Protection circuit | Reverse polarity protection circuit | ||||
| Analog output | Voltage output | • Output voltage: 1-5VDC ±2% F.S. • Linear: Max. ±1% F.S. • Output impedance: 1kΩ | |||
| Current output | • Output current: DC4-20mA ±2% F.S. • Linear: Max. ±1% F.S. | ||||
| Temp. characteristics of analog output | Max. ±2% F.S. of output voltage/current at 25℃ within temperature range 0 to 50℃ | ||||
| Insulation resistance | Over 50MΩ (at 500VDC megger) | ||||
| Dielectric strength | 2000VAC 50/60Hz for 1 minute | ||||
| Vibration | 1.5mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours | ||||
| Environment | Ambient temp. | 0 to 50℃, storage: -10 to 60℃ | |||
| Ambient humi. | 35 to 85%RH, storage: 35 to 85%RH | ||||
| Protection structure | IP40 (IEC standard) | ||||
| Material | Front, Rear case: Polycarbonate, Pressure port: Nickel plated brass | ||||
| Cable | Ø3, 4-wire, 3m (AWG28, Core diameter: 0.08mm, Number of cores: 19, Insulator out diameter: Ø0.88mm) | ||||
| Sold separately | Sensor connector wire mount plug (CNE-P04- )※1 | ||||
| Approval | CE | ||||
| Weight※2 | Approx. 60g (approx. 26g) | ||||
 
								