CA8336 Power Quality Analyzer

The CA8336 Power Quality Analyzer is a three-phase, multi-function, intelligent, and simple comprehensive test instrument specially developed for on-site testing. It is easy to use, large LCD color screen display, high resolution, bilingual operation interface in Chinese and English, and vibration-proof structure shell.

It can measure 4 currents (ABC three-phase and neutral wire current),4 voltages (ABC three-phase voltage and neutral wire-to-ground voltage), the peak value of current and voltage, the maximum and minimum values within period of time, three-phase current Balance, short-term voltage flicker, transformer K factor, active power, reactive power, apparent power, power factor, displacement power factor, active energy, reactive energy, apparent energy, harmonic ratio, total harmonic distortion, display current and voltage real-time waveforms, phasor diagrams, and harmonic ratio bar graphs; dynamically capture instantaneous changes in voltage and current, monitor starting current, monitor various power parameters and generate alarm events list, record test data fora long time and generate trend curves Picture and other various functions.

Contact us

Features

  • Real-time monitoring of power quality parameters
  • Reports and charts can be provided
  • Improve the reliability and stability of the power grid
  • Power quality analysis, diagnosis of grid quality
  • Remote monitoring, real time monitor power quality
  • Failure early warning, detection of potential equipment failures
  • Can record historical data to facilitate analysis and prediction of power quality change trends
  • Automatic alarm, automatically send an alarm signal when the power quality is abnormal
  • Optimize grid operation, reduce energy consumption, and improve grid efficiency

 

Application

  • Energy Metering and Billing
  • Smart grid construction and operation
  • Power system operation monitoring and analysis
  • Industrial production equipment power quality monitoring and analysis
  • Power quality improvement program design and implementation
  • Power system installation and operation inspection
  • Construction and operation monitoring of renewable energy power stations
  • power quality monitoring and management

Specification

Parameter Value
Frequency 40-69Hz
True RMS Voltage 2-1000V
True RMS Line Voltage 1.0-2000V / 0.1 / ±(0.5%+5dgt)
DC Voltage 2-1000V
True RMS Current 100mA-10000A
Phase Voltage Peak 1.0-1414V / 0.1 / ±(1.0%+5dgt)
Neutral Line voltage Peak 1.0-2828V / 0.1 / ±(1.0%+5dgt)
Current Peak 10mA-6000A / 1mA / ±(1.0%+5dgt)
CF 1.0~3.99 / 0.01 / ±(1%+2dgt)
4~9.99 / 0.01 / ±(5%+2dgt)
Active Power 0.000W-9999.9kW / 0.001W / ±(1%+3dgt)@PF>0.8
0.000W-9999.9kW / 0.001W / ±(1.5%+10dgt)@0.2<PF<0.8
Reactive Power, inductive or
capacitive
0.000Var-9999.9kVar / 0.001Var / ±(1%+3dgt)@PF<-0.5
0.000Var-9999.9kVar / 0.001Var / ±(1.5%+10dgt)@-0.5<PF<-0.2
Apparent Power 0.000VA-9999.9kVA / 0.001VA / ±(1%+3dgt)
Power Factor -1.000~1.000 / 0.001 / ±(1.5%+3dgt)@PF>0.5
-1.000~1.000 / 0.001 / ±(1.5%+10dgt)@0.2<PF<0.5
Active Electrical Energy 0.000Wh-9999.9MWh / 0.001Wh / ±(1%+3dgt)@PF>0.8
0.000Wh-9999.9MWh / 0.001Wh / ±(1.5%+10dgt)@0.2<PF<0.8
Reactive Electrical Energy, Inductive or Capacitive 0.000Varh-9999.9MVarh / 0.001Varh / ±(1%+3dgt)@PF<-0.5
0.000Varh-9999.9MVarh / 0.001Varh / ±(1.5%+10dgt)@-0.5<PF<-0.2
Apparent Electrical Energy 0.000VAh-9999.9MVAh / 0.001VAh / ±(1%+3dgt)
Phase Angle -179°~180° / 1° / ±2°
Tanφ (VA≥50VA) -32.76~32.76 / 0.001 / φ:±1°
DPF -1.000~1.000 / 0.001 / φ:±1°
Harmonic Ratio 1~50
(Vrms>50V)
0.0%~99.9% / 0.1% / ±(1%+5dgt)@1-20th
0.0%~99.9% / 0.1% / ±(1%+10dgt)@1-20th
0.0%~99.9% / 0.1% / ±(1%+15dgt)@1-20th
Harmonic Angle
(Vrms>50V)
-179°~180° / 1° / ±3°@1-25th
-179°~180° / 1° / ±10°@26-50th
Total Harmonic
Ratio (THD or THDF)≤50
0.0%~99.9% / 0.1% / ±(1%+5dgt)@1-20th
0.0%~99.9% / 0.1% / ±(1%+10dgt)@1-20th
0.0%~99.9% / 0.1% / ±(1%+15dgt)@1-20th
Distortion Factor
(DF or THD-R)≤50
-179°~180° / 1° / ±3°@1-25th
-179°~180° / 1° / ±10°@26-50th
Transformer K Factor 0.0%~99.9% / 0.1% / ±(1%+10dgt)
3 Phase Unbalance 0.0%~99.9% / 0.1% / ±(1%+10dgt)
Expert mode
Harmonic 0-50th
Total Harmonic distortion √ Per phase
Number of Transient Record 210 groups
Voltage Flicker √ / error 5%
Inrush current √ >10MIN
Three Phase Unbalance √ Error 0.3%
Record √ 2 weeks – several years
Min/Max
Alarm 40 different types 10000 times
Peak Value
Comm port USB
Enclosure protection class IP 53 / IK08
Safety Regulation IEC-61010,CATIII 1000V/IEC61010-31/IEC61326
Display Mode 240x170x68mm
Instrument Weight

 

1.9 kg

 

Instrument Weight 1.6kgs(with battery),
power adapter0.9kgs,Packing size with protective box and transformer, <15KGS
Power 9.6V Ni-MH rechargeable battery
Power Consumption more than 13 hours
Memory 2G
Waveform real-time display 5 voltages/4 currents