Features of Eaton Automatic Transfer Switch
- Accessible in three transition types: closed, open in-phase, and open delayed.
- Both automated and manual modes of operation have a double-throw, interlocked power switch powered by a sturdy solenoid operating mechanism.
- Eaton’s Arcflash Reduction Maintenance System offers a service entry-rated option to lower incident energy levels for downstream equipment during maintenance intervals.
- Types of enclosures: indoor and outdoor
- Seismic-approved integrated Cam-Lok receptacle power panel, listed to UL 1008 and CSA 22.2 No. 178, that doubles as a docking station for an instantaneous connection of a portable or temporary generator
Applications of Eaton Automatic Transfer Switch
- Construction of contactors and circuit breakers
- Transition switching between open (time-delayed, in-phase, load voltage decay) and closed
- Isolation bypass functionality
- Remote annunciator and controller for automatic transfer switches (ATS) built-in overcurrent defense
Specification of Eaton Automatic Transfer Switch
| Contactor | Molded Case | Power Frame | Bypass Isolation | Contactor | |
| Application Standard
configuration |
Yes | Yes | Yes | ||
| Bypass isolation | Yes | Yes | |||
| Service entrance 1 | Yes | Yes | Yes | Yes | Yes |
| Overcurrent protection | Yes | Yes | Yes | Yes | Yes |
| ArcFlash Reduction Maintenance System (ARMS) |
Yes |
Yes |
Yes |
Yes |
Yes |
| Integral generator docking station (Cam-Lok) | Yes | Yes | Yes | Yes | Yes |
| Integral load bank docking station (Cam-Lok) | Yes | Yes | Yes | Yes | |
| Electrical Amperage | 40 – 3000 A | 40 – 1000 A | 200 – 5000 A | 100 – 3000 A | 200 – 5000 A |
| Voltage | up to 600 Vac | up to 600 Vac | up to 600 Vac | up to 600 Vac | up to 600 Vac |
| Frequency | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz |
|
AC power system |
single and three-phase | single and three-phase | single and three-phase | single and three-phase | single and three-phase |
| Wire configuration | 3 or 4-wire | 3 or 4-wire | 3 or 4-wire | 3 or 4-wire | 3 or 4-wire |
| Power poles | 2, 3, 4 | 2, 3, 4 | 2, 3, 4 | 2, 3, 4 | 2, 3, 4 |
| Transition Open | Yes | Yes | Yes | Yes | Yes |
| Open (time delayed) | Yes | Yes | Yes | Yes | Yes |
| Open (load voltage decay) | Yes | Yes | Yes | Yes | Yes |
| Open (in-phase) | Yes | Yes | Yes | Yes | |
| Closed (with fallback to open option) |
Yes |
Yes |
Yes |
Yes |
|
| Operation Automatic | Yes | Yes | Yes | Yes | Yes |
| Non-Automatic | Yes | Yes | Yes | Yes | Yes |
| Manual | Yes 2 | Yes | Yes | Yes 2 | Yes |
| Neutral Solid
configuration |
Yes | Yes | Yes | Yes | Yes |
| Switched | Yes | Yes | Yes | Yes | Yes |
| Enclosure type NEMA | 1, 3R, 4X, 12 | 1, 3R, 4X, 12 | 1, 3R, 3RX | 1, 3R, 4X, 12 | 1, 3R, 3RX |
| Product UL 1008 listed
standard CSA C22.2 No. 178.1 certified |
Yes
Yes |
Yes
Yes |
Yes
Yes |
Yes
Yes |
Yes
Yes |