Feature
- A fully welded sensor housing providing a hermetic seal for maximum protection.
- A removable and replaceable terminal block that enables repairs in the field to avoid process shutdown.
- Any potential process fluid leakage is captured with an optional secondary containment compartment to surround the electrodes.
- An all-welded sensor housing ensures reliability in harsh environments.
- An optional lining protector guards against installation damage and leading-edge wear.
- An obstruction-less design features no moving parts and minimised maintenance and repair.
Specifications
- Accuracy: Up to 0.15% of volumetric flow rate accuracy over 13:1 flow turndowns, 0.25% over 40:1 flow turndown.
- Line Sizes: ½-36 inch (15-900 mm).
- Liner Materials: PTFE, ETFE, PFA, Polyurethane, Neoprene, Linatex Natural Rubber.
- Electrode Materials: 316L Stainless Steel, Nickel Alloy, Platinum, Tantalum, Titanium.
- Flange Ratings: ASME B16.5 Class 150-2500DIN PN 10-40AS 2129 Table D and EAWWA C207 Table 3 Class D (30-36 inch only).
- Submergence Protection: IP68 (Recommended with sealed cable glands).
- Interchangeability:
- Compatible with all 8700 Series transmitters.
- Compatible with legacy transmitters: 8712D, 8712C, 8732C, 8742C.