Features
- AEC-Q200 qualified (rev. D) up to 110 °C for ≤ 470 nF
- Compliant with IEC 60381-14: AMD1 grade IB
- THB: 85 °C / 85 % RH, 168 h at URAC
Application
- High stability grade for continuous across the line X2 applications.
- For the maximum product dimensions and maximum space requirements for length (lmax.), width (wmax.) and height (hmax.) following tolerances must be taken in account in the envelopment of the components as shown in the drawings below.
Specification
QUICK REFERENCE DATA | |
Capacitance range (E12 series) | 0.01 μF to 2.2 μF (preferred values acc. to E6) |
Capacitance tolerance | ± 10 %, ± 20 % (± 5 % on request) |
Rated AC voltage | 310 VAC; 50 Hz to 60 Hz |
Permissible DC voltage | 800 VDC at 85 °C
630 VDC at 110 °C |
Climatic testing class according to IEC 60068-1 | 40/110/56/C |
Maximum application temperature | 110 °C |
Reference standards |
IEC 60384-14 ed-4 and EN 60384-14
IEC 60065 pass. flamm. class C CSA-E384-14 UL 60384-14 |
Dielectric | Polyester film |
Electrodes | Metallized |
Construction |
Series construction |
Encapsulation | Plastic case, epoxy resin sealed, flame retardant UL-class 94 V-0 |
Leads | Tinned wire |
Marking |
C-value; tolerance; rated voltage; sub-class; manufacturer’s type; code for dielectric material; manufacturer location, year and week; manufacturer’s logo or name; safety approvals |
DESCRIPTION | VALUE |
Rated AC voltage (URAC) | 310 V |
Permissible DC voltage (URDC) | 630 V |
Tangent of loss angle | £ 100 x 10-4 at 1 kHz |
Rated voltage pulse slope at (dU/dt)R 435 VDC | 100 V/μs |
R between leads, for C £ 0.33 μF at 100 V; 1 min | > 15 000 MÙ |
RC between leads, C > 0.33 μF at 100 V; 1 min | > 5000 s |
R between leads and case; 100 V; 1 min | > 30 000 MÙ |
Withstanding (DC) voltage (cut off current 10 mA) (1); rise time £ 1000 V/s C £ 0.47 μF
C > 0.47 μF |
2200 V; for 1 min 2150 V; for 1 min |
Withstanding (AC) voltage between leads and case | 2120 V; 1 min |
Maximum application temperature | 110 °C |