Fluke 1775 Power Quality Analyzer

The Fluke 1775 Power Quality Analyzer is a three-phase, multi-function, intelligent, and simple comprehensive test instrument specially developed for on-site testing. It is easy to use, large LCD color screen display, high resolution, bilingual operation interface in Chinese and English, and vibration-proof structure shell.

It can measure 4 currents (ABC three-phase and neutral wire current),4 voltages (ABC three-phase voltage and neutral wire-to-ground voltage), the peak value of current and voltage, the maximum and minimum values within period of time, three-phase current Balance, short-term voltage flicker, transformer K factor, active power, reactive power, apparent power, power factor, displacement power factor, active energy, reactive energy, apparent energy, harmonic ratio, total harmonic distortion, display current and voltage real-time waveforms, phasor diagrams, and harmonic ratio bar graphs; dynamically capture instantaneous changes in voltage and current, monitor starting current, monitor various power parameters and generate alarm events list, record test data fora long time and generate trend curves Picture and other various functions.

Contact us

Features

  • Real-time monitoring of power quality parameters
  • Reports and charts can be provided
  • Improve the reliability and stability of the power grid
  • Power quality analysis, diagnosis of grid quality
  • Remote monitoring, real time monitor power quality
  • Failure early warning, detection of potential equipment failures
  • Can record historical data to facilitate analysis and prediction of power quality change trends
  • Automatic alarm, automatically send an alarm signal when the power quality is abnormal
  • Optimize grid operation, reduce energy consumption, and improve grid efficiency

 

Application

  • Energy Metering and Billing
  • Smart grid construction and operation
  • Power system operation monitoring and analysis
  • Industrial production equipment power quality monitoring and analysis
  • Power quality improvement program design and implementation
  • Power system installation and operation inspection
  • Construction and operation monitoring of renewable energy power stations
  • power quality monitoring and management

Specification

Parameter Value
Frequency 40-70Hz / 0.01Hz / ±0.03Hz
True RMS Voltage 1.0-1000V / 0.1 / ±(0.5%+5dgt)
True RMS Line Voltage 1.0-2000V / 0.1 / ±(0.5%+5dgt)
DC Voltage 1.0-1000V / 0.1 / ±(1.0%+5dgt)
True RMS Current 10mA-6000A / 1mA / ±(0.5%+5dgt)
Phase Voltage Peak 1.0-1414V / 0.1 / ±(1.0%+5dgt)
Neutral Line voltage Peak 1.0-2828V / 0.1 / ±(1.0%+5dgt)
Current Peak 10mA-6000A / 1mA / ±(1.0%+5dgt)
CF 1.0~3.99 / 0.01 / ±(1%+2dgt)
4~9.99 / 0.01 / ±(5%+2dgt)
Active Power 0.000W-9999.9kW / 0.001W / ±(1%+3dgt)@PF>0.8
0.000W-9999.9kW / 0.001W / ±(1.5%+10dgt)@0.2<PF<0.8
Reactive Power, inductive or
capacitive
0.000Var-9999.9kVar / 0.001Var / ±(1%+3dgt)@PF<-0.5
0.000Var-9999.9kVar / 0.001Var / ±(1.5%+10dgt)@-0.5<PF<-0.2
Apparent Power 0.000VA-9999.9kVA / 0.001VA / ±(1%+3dgt)
Power Factor -1.000~1.000 / 0.001 / ±(1.5%+3dgt)@PF>0.5
-1.000~1.000 / 0.001 / ±(1.5%+10dgt)@0.2<PF<0.5
Active Electrical Energy 0.000Wh-9999.9MWh / 0.001Wh / ±(1%+3dgt)@PF>0.8
0.000Wh-9999.9MWh / 0.001Wh / ±(1.5%+10dgt)@0.2<PF<0.8
Reactive Electrical Energy, Inductive or Capacitive 0.000Varh-9999.9MVarh / 0.001Varh / ±(1%+3dgt)@PF<-0.5
0.000Varh-9999.9MVarh / 0.001Varh / ±(1.5%+10dgt)@-0.5<PF<-0.2
Apparent Electrical Energy 0.000VAh-9999.9MVAh / 0.001VAh / ±(1%+3dgt)
Phase Angle -179°~180° / 1° / ±2°
Tanφ (VA≥50VA) -32.76~32.76 / 0.001 / φ:±1°
DPF -1.000~1.000 / 0.001 / φ:±1°
Harmonic Ratio 1~50
(Vrms>50V)
0.0%~99.9% / 0.1% / ±(1%+5dgt)@1-20th
0.0%~99.9% / 0.1% / ±(1%+10dgt)@1-20th
0.0%~99.9% / 0.1% / ±(1%+15dgt)@1-20th
Harmonic Angle
(Vrms>50V)
-179°~180° / 1° / ±3°@1-25th
-179°~180° / 1° / ±10°@26-50th
Total Harmonic
Ratio (THD or THDF)≤50
0.0%~99.9% / 0.1% / ±(1%+5dgt)@1-20th
0.0%~99.9% / 0.1% / ±(1%+10dgt)@1-20th
0.0%~99.9% / 0.1% / ±(1%+15dgt)@1-20th
Distortion Factor
(DF or THD-R)≤50
-179°~180° / 1° / ±3°@1-25th
-179°~180° / 1° / ±10°@26-50th
Transformer K Factor 0.0%~99.9% / 0.1% / ±(1%+10dgt)
3 Phase Unbalance 0.0%~99.9% / 0.1% / ±(1%+10dgt)
Expert mode
Harmonic 0-50th
Total Harmonic distortion √ Per phase
Number of Transient Record
Voltage Flicker
Inrush current
Motor Starting Current detect 100s
Record 300 days @1 minute interval, 20 parameters each time
Alarm 12800 groups of alarm records, 40 kinds of parameters are optional
Peak Value
Screenshot Capacity 60
Comm port USB
Withstand Voltage 1min @ 3700Vac/50Hz,Case to line
Insulation 10MΩ
Safety Regulation IEC-61010,CATIII 1000V/IEC61010-31/IEC61326
Display Mode 640*480, 5.6inch, 116x88mm
Display Mode 240x170x68mm
Instrument Weight 1.6kgs(with battery),
power adapter0.9kgs,Packing size with protective box and transformer, <15KGS
Power 11.1V 7800mAhRechargeable lithium ion battery
Power Consumption 410mA, fully charged for 15 hours
Memory X (factory standard 32G memory card, can be replaced)
Waveform real-time display 4 voltages/4 currents