FXD Microprocessor-Based Recloser Control

The FXD recloser control is the latest in a series of fully integrated controls developed by Cooper Power Systems, ready for the Smart  Grid. It is designed as a smart and reliable solution to meet your requirements for ease-of-use, simplicity, and future upgradeability.

Additional functions are provided as options depending on your requirements.

The control is housed in a weatherproof cabinet to ensure reliability. In addition, it can be housed separately from the recloser as they are connected via cable.

The control is easy to operate as it adopts a standard look and feel with a universal platform that can be used for almost any protective application. This means that field engineers need only learn ONE standard operating system and application to maintain MULTIPLE protective applications.

Contact us
Category:

Feature:

  • A smart and reliable solution designed for easy mainte­ nance and future upgradeabili­ ty.
  • Offers flexible phase and ground overcurrent protection for the main feeder, and provides power quality monitoring and metering.
  • Contains modular compo nents (control module, power supply module, cabinet, heater, and MCCB) that are easy to maintain and service.
  • The control panel of the recloser is interactive, with programmable soft keys and large interface push-buttons to allow for single push activation of commonly used control functions. Its LED indicators show the current status of the recloser.
  • The control is password protected and housed in a weatherproof cabinet that can be padlocked.
  • With cables connections to the recloser, the control can also be housed separately from the recloser.
  • Maximum/minimum phase and ground demand current values.
  • Overfrequency/ Underfrequency Protection.
  • Overvoltage/ Undervoltage Protection.
  • Simulator to test metering and protection function with virtual current and voltage injection.
  • An impedance-based fault locator to calculate the distance by impedance calculation.
  • Loss of phase protection trips the recloser if phase-earth voltage on one or two phases falls below a defined voltage threshold.
  • Smart Phone application for metering, data access, operation and positioning.
  • Sync-check capability based on source side ane load side PT to qualify close signal to the mechanism when enabled via the sync check settings.
  • Duty cycle monitor to measure and record duty in non-volatile memory.

Specifications

Rated voltage
40.5KV
Rated current
2500
Rated short-circuit breaking current
20KA,25KA,31.5KA
Rated short-circuit making current
50KA,63KA, 80KA
Rated peak withstand current
50KA,63KA, 80KA
4s rated short-circuit withstand current
20KA,25KA,31.5KA
Rated operating sequence
On-0.3s-off on-180s-off on
Mechanical life
10000times
Rated operation sequence
O-0.3s-CO -180s-CO
Rated breaking current of capacitor bank
400A