GF Signet 3-2551-P0-12 GF Signet Magmeter Flow Sensor without Display

GF Signet 3-2551-P0-12 GF Signet Magmeter is an insertion-style electromagnetic flow meter with corrosion-resistant materials that provide long-term reliability and low maintenance. It is available in a wide range of pipe sizes, from DN15 to DN900 (½-inch to 36-inch). It has multiple output options for use with a variety of controllers and systems and features empty pipe detection and LED-assisted diagnostics. The user can customize the flow meter’s performance to suit specific application needs using the Signet 3-0252 Configuration Tool.

Contact us

Features of GF Signet Magmeter

  • Sensor Body – Polypropylene and 316L SS
  • 4 to 20 mA output
  • Installs into pipe sizes DN15 to DN100 (1/2″ to 4″)
  • Patented Magmeter technology
  • No moving parts
  • Bi-directional flow
  • Empty pipe detection
  • Operating range: 0.05 to 10 m/s (0.15 to 33 ft/s)
  • Accurate measurement even in dirty liquids
  • Polypropylene or PVDF retaining nuts
  • No pressure drop
  • Corrosion-resistant materials; PP or PVDF with SS, Hastelloy-C, or Titanium
  • Multi-language display menu available

Application of GF Signet Magmeter

  • Chemical Processing
  • Water and Wastewater Monitoring
  • Metal Recovery
  • Landfill Leachate
  • Commercial Pools, Spas and Aquariums
  • HVAC
  • Scrubber control
  • Neutralization Systems
  • Industrial Water Distribution

Specification of GF Signet Magmeter

General
Operating Range 0.05 to 10 m/s 0.15 to 33 ft/s
Pipe Size Range DN15 to DN900 ½ in. to 36 in.
Linearity ± 1% reading plus 0.1% of full scale
Repeatability ±0.5% of reading @ 25 °C (77 °F)
Minimum Conductivity 20 μS/cm
Wetted Materials
Sensor Body/Electrodes
and Grounding Ring
-P0, -P1, -P2: PP/316L SS
-T0, -T1, -T2: PVDF/Titanium
-V0, -V1, -V2: PVDF/Hastelloy-C
O-rings FPM (standard)
EPR (EPDM), FFPM (optional)
Case PBT
Display Window Polyamide (transparent nylon)
Protection Rating NEMA 4X/IP65
Electrical
Power Requirements 4 to 20 mA 24 VDC ±10%, regulated, 22.1 mA max.
Frequency 5 to 24 VDC ±10%, regulated, 15 mA max.
Digital (S3L) 5 to 6.5 VDC, 15 mA max.
Auxiliary (only required for units with relays) 9 to 24 VDC, 0.4 A max.
Reverse Polarity and Short Circuit Protected
Current Output 4 to 20 mA Loop Accuracy 32 μA max. error (25 °C @ 24 VDC)
Isolation Low voltage < 48 VAC/DC from electrodes and auxiliary power
Maximum Cable 300 m (1000 ft)
Error condition 22.1 mA
Max. Loop Resistance 300 Ω
Compatible with PLC, PC or similar equipment
4 to 20 mA load needed
Frequency Output Output Modes Freq., or Mirror Relay (display version only)
Max. Pull-up Voltage 30 VDC
Max. Current Sink 50 mA, current limited
Maximum Cable 300 m (1000 ft)
Compatible with Signet Model 8550, 8900, 9900, 9900-1BC
Digital (S3L) Output Serial ASCII, TTL level 9600 bps
Compatible with Model Signet 8900 controller
Relay Specifications
#1, #2 Type Mechanical SPDT
Rating 5 A @ 30 VDC max., 5 A @ 250 VDC max.
#3 Type Solid State
50 mA @ 30 VDC, 50 mA @ 42 VAC
Hysteresis User adjustable for exiting alarm condition
Alarm On Trigger Delay Adjustable (0 to 9999.9 sec.)
Relay Modes Off , Low, High, Window, and Proportional Pulse
Relay Source Flow Rate, Resettable Totalizer
Error Condition Selectable; Fail Open or Closed
Display
Characters 2 x 16
Contrast User-set in four levels
Backlighting (only on relay versions) Requires external 9-24 VDC, 0.4 mA max.
Max. Temperature/Pressure Rating
Storage Temperature -20 °C to 70 °C -4 °F to 158 °F
Relative Humidity 0 to 95% (non-condensing)
Operating Temperature Ambient -10 °C to 70 °C 14 °F to 158 °F
Media 0 °C to 85 °C 32 °F to 185 °F
Maximum Operating Pressure 10.3 bar @ 25 °C 150 psi @ 77 °F
1.4 bar @ 85 °C 20 psi @ 185 °F
Shipping Weight
0.680 kg 1.50 lb
Standards and Approvals
CE, FCC, UL, CUL, NSF (3-2551-PX-XX version only)
RoHS compliant, China RoHS
NEMA 4X / IP65 Enclosure (with cap installed)
Manufactured under ISO 9001 for Quality and ISO 14001 for Environmental Management and OHSAS 18001 for Occupational Health and Safety