GF Signet 3-2551-P0-42 Signet Magmeter Flow Sensor with Display

GF Signet’s 3-2551-P0-42 Signet Magmeter Flow Sensor for DN15 to DN100 (1/2″ to 4″) Pipe Sizes with a display equipped with a Polypropylene and 316L SS sensor body.

Contact us

The GF Signet 2551 Magmeter measures the flow rate in a full pipe by monitoring the voltage produced when the (conductive) fluid moves through a magnetic field. The GF signet flow meter 2551 offers three GF Signet flow instrumentation output options using a frequency or digital (S³L) sensor output. The 4-20mA output can be used for direct input to PLCs, chart recorders, etc. The 4-20mA output and digital (S³L) sensor interface are available for long-distance signal transmission of up to 1,000 ft. The GF Signet 2551 with a built-in display can be used for permanent and resettable totals. The display contains multiple languages with English, Spanish, German, French, Italian, and Portuguese menu options.

Features of GF Signet 2551 Magmeter Flow Sensor

  • Sensor Body – Polypropylene and 316L SS
  • 4 to 20 mA output
  • Installs into pipe sizes DN15 to DN100 (1/2″ to 4″)
  • Patented Magmeter technology
  • No moving parts
  • Bi-directional flow
  • Empty pipe detection
  • Operating range: 0.05 to 10 m/s (0.15 to 33 ft/s)
  • Accurate measurement even in dirty liquids
  • Polypropylene or PVDF retaining nuts
  • No pressure drop
  • Corrosion-resistant materials; PP or PVDF with SS, Hastelloy-C, or Titanium
  • Multi-language display menu available

Standards:

  • CE
  • UL
  • CUL
  • FCC
  • RoHS compliant
  • China RoHS
  • NSF (3-2551-PX-XX version only)

 

Specification of GF Signet 2551 Magmeter Flow Sensor

General
Operating Range 0.05 to 10 m/s 0.15 to 33 ft/s
Pipe Size Range DN15 to DN900 ½ in. to 36 in.
Linearity ± 1% reading plus 0.1% of full scale
Repeatability ±0.5% of reading @ 25 °C (77 °F)
Minimum Conductivity 20 μS/cm
Wetted Materials
Sensor Body/Electrodes
and Grounding Ring
-P0, -P1, -P2: PP/316L SS
-T0, -T1, -T2: PVDF/Titanium
-V0, -V1, -V2: PVDF/Hastelloy-C
O-rings FPM (standard)
EPR (EPDM), FFPM (optional)
Case PBT
Display Window Polyamide (transparent nylon)
Protection Rating NEMA 4X/IP65
Electrical
Power Requirements 4 to 20 mA 24 VDC ±10%, regulated, 22.1 mA max.
Frequency 5 to 24 VDC ±10%, regulated, 15 mA max.
Digital (S3L) 5 to 6.5 VDC, 15 mA max.
Auxiliary (only required for units with relays) 9 to 24 VDC, 0.4 A max.
Reverse Polarity and Short Circuit Protected
Current Output 4 to 20 mA Loop Accuracy 32 μA max. error (25 °C @ 24 VDC)
Isolation Low voltage < 48 VAC/DC from electrodes and auxiliary power
Maximum Cable 300 m (1000 ft)
Error condition 22.1 mA
Max. Loop Resistance 300 Ω
Compatible with PLC, PC or similar equipment
4 to 20 mA load needed
Frequency Output Output Modes Freq., or Mirror Relay (display version only)
Max. Pull-up Voltage 30 VDC
Max. Current Sink 50 mA, current limited
Maximum Cable 300 m (1000 ft)
Compatible with Signet Model 8550, 8900, 9900, 9900-1BC
Digital (S3L) Output Serial ASCII, TTL level 9600 bps
Compatible with Model Signet 8900 controller
Relay Specifications
#1, #2 Type Mechanical SPDT
Rating 5 A @ 30 VDC max., 5 A @ 250 VDC max.
#3 Type Solid State
50 mA @ 30 VDC, 50 mA @ 42 VAC
Hysteresis User adjustable for exiting alarm condition
Alarm On Trigger Delay Adjustable (0 to 9999.9 sec.)
Relay Modes Off , Low, High, Window, and Proportional Pulse
Relay Source Flow Rate, Resettable Totalizer
Error Condition Selectable; Fail Open or Closed
Display
Characters 2 x 16
Contrast User-set in four levels
Backlighting (only on relay versions) Requires external 9-24 VDC, 0.4 mA max.
Max. Temperature/Pressure Rating
Storage Temperature -20 °C to 70 °C -4 °F to 158 °F
Relative Humidity 0 to 95% (non-condensing)
Operating Temperature Ambient -10 °C to 70 °C 14 °F to 158 °F
Media 0 °C to 85 °C 32 °F to 185 °F
Maximum Operating Pressure 10.3 bar @ 25 °C 150 psi @ 77 °F
1.4 bar @ 85 °C 20 psi @ 185 °F
Shipping Weight
0.680 kg 1.50 lb
Standards and Approvals
CE, FCC, UL, CUL, NSF (3-2551-PX-XX version only)
RoHS compliant, China RoHS
NEMA 4X / IP65 Enclosure (with cap installed)
Manufactured under ISO 9001 for Quality ISO 14001 for Environmental Management and OHSAS 18001 for Occupational Health and Safety

Application of GF Signet 2551 Magmeter Flow Sensor

  • Chemical processing
  • Water and wastewater monitoring
  • Metal recovery and landfill leachate
  • Commercial pools, spas, and aquariums
  • HVAC
  • Scrubber control
  • Neutralization systems
  • Industrial water distribution