HAKEL HIG95-DELTA Hospital Insulation Monitoring Device

HAKEL HIG95-DELTA Insulation monitoring device is specially used to monitor the insulation resistance in hospital equipment. It is compatible with current transformers and temperature sensors to monitor the current thermal overload of medical transformers in the IT system.

  • RS485 communication interface & ISOLGUARD protocol
  • Insulation monitoring devices for healthcare IT systems
  • Supported module of distant signalization
  • Meeting IEC 61557 Standard
  • Equipped with display

 

Contact us

HAKEL HIG95-DELTA is a high-performance insulation monitoring device produced by the Czech HAKEL company, mainly used to monitor the insulation resistance of AC systems. It is widely used in the medical field to provide reliable insulation protection for various equipment.

Feature of HAKEL HIG95-DELTA

  • Accurately measure insulation resistance: It can accurately measure insulation resistance, detect insulation faults in time, and prevent equipment damage.
  • Versatility: It supports a variety of temperature sensors, which can monitor insulation resistance and equipment temperature at the same time for comprehensive monitoring.
  • Easy to operate: Equipped with a display screen, it is easy to operate and easy to set up.
  • High reliability: It uses high-quality materials, is durable, and can operate stably in harsh environments.
  • Powerful communication function: It supports RS485 communication, which is convenient for remote monitoring and data management.
  • Meet the requirements of the medical industry: It meets the high standards of medical equipment for insulation monitoring.

 

Specification of HAKEL HIG95-DELTA

Monitored IT power supply system type according to IEC 61557-8 AC, MED
Insulation resistance measuring range(RF) 5 ÷ 10 000 kΩ
Adjustable range of critical insulation resistance 50 ÷ 500 kΩ
Number of insulation resistance fault levels (Ran) 1
Rated voltage of monitored IT system (AC) 230 V
IMD power supply From measured IT system
Supply voltage range 85-264Vac
Monitoring of current overload of medical transformer using current transformers
Monitoring of thermal overload of medical transformer  temperature sensor is connected straight to the IMD
Supported temperature sensors 1x PT100, 2x PT100, 1x NC contact, 2x NC contact, 1x PTC thermistor, 2x PTC thermistor
Power consumption 4 VA
Measuring voltage 12 V (common medical voltage value)
Measuring current < 0.6 mA, 2CT, 5A
Measuring input’s internal impedance > 1 000 kΩ, 5KΩ-10MΩ
Measuring accuracy ± 10 %
Electrical strength against internal circuits 3kV
Supported module of distant signalisation (MDS) MDS-D, MDS-DELTA
Communication RS485 bus, ISOLGUARD
protection of front panel IP40
protection except the front panel IP20
Operating temperature – 10 ÷ 60 °C
Installation  DIN rail 35 mm
Modular width 2
standards IEC 61557
IEC 60664
HD 60364

 

HAKEL HIG95-DELTA Dimension

Dimension of HAKEL HIG95-DELTA hospital insulation monitoring relay

HAKEL HIG95-DELT Wiring Diagram

wiring of HAKEL HIG95-DELTA IMD Insulation Monitoring