HDR-60 series 60W Ultra Slim Step Shape DIN Rail

Contact us

Feature

  • Ultra slim design with 52.5mm(3SU} width
  • Universal input 85~264VAC(277VAC operational}
  • No load power consumption<0.3W
  • lsolation class Ⅱ
  • Pass LPS (Limited power source)
  • DC output voltage adjustable
  • Protections : Short circuit / Overload / Over voltage
  • Cooling by free air convection (working temperature:-30~+70°C)
  • DIN rail TS-35/7.5 or 15 mountable
  • LED indicator for power on
  • 3 years warranty

Application

  • Industrial control system
  • Mechanical and electrical equipment
  • Electronic instruments
  • Test and measurement instrument
  • Laser related machine
  • Charging related equipment
  • Household appliances
  • Power Sourcing Equipment of PoE

 

Specification

 

MODEL HDR-60-5 HDR-60-12 HDR-60-15 HDR-60-24 HDR-60-48
 

 

 

 

 

 

 

OUTPUT

DC VOLTAGE 5V 12V 15V 24V 48V
RATED CURRENT 6.5A 4.5A 4A 2.5A 1.25A
CURRENT RANGE 0 ~ 6.5A 0 ~ 4.5A 0 ~ 4A 0 ~ 2.5A 0 ~ 1.25A
RATED POWER 32.5W 54W 60W 60W 60W
RIPPLE & NOISE (max.) Note.2 80mVp-p 120mVp-p 120mVp-p 150mVp-p 240mVp-p
VOLTAGE ADJ. RANGE 5.0 ~ 5.5V 10.8 ~ 13.8V 13.5 ~ 18V 21.6 ~ 29V 43.2 ~ 55.2V
VOLTAGE TOLERANCE Note.3 ±2.0% ±1.0% ±1.0% ±1.0% ±1.0%
LINE REGULATION ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
LOAD REGULATION ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
SETUP, RISE TIME 500ms, 50ms/230VAC         500ms, 50ms/115VAC at full load
HOLD UP TIME (Typ.) 30ms/230VAC        12ms/115VAC at full load
 

 

 

INPUT

VOLTAGE RANGE 85 ~ 264VAC (277VAC operational )     120 ~ 370VDC (390VDC operational )
FREQUENCY RANGE 47 ~ 63Hz
EFFICIENCY (Typ.) 85% 88% 89% 90% 91%
AC CURRENT (Typ.) 1.2A/115VAC         0.8A/230VAC
INRUSH CURRENT (Typ.) COLD START 30A/115VAC         60A/230VAC
 

 

 

PROTECTION

 

OVERLOAD

105 ~ 160% rated output power
Hiccup mode when output voltage <50%, recovers automatically after fault condition is removed

Constant current limiting within 50% ~100% rated output voltage, recovers automatically after fault condition is removed

 

OVER VOLTAGE

5.75 ~ 6.75V 14.2 ~ 16.2V 18.8 ~ 22.5V 30 ~ 36V 56.5 ~ 64.8V
Protection type : Shut down o/p voltage, re-power on to recover
 

 

 

ENVIRONMENT

WORKING TEMP. -30 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY -40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT ±0.03%/℃ (0 ~ 50℃) RH non-condensing
VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
OPERATING ALTITUDE 2000 meters
OVER VOLTAGE CATEGORY Ⅲ; According to EN61558, EN50178,EN60664-1, EN62477-1; altitude up to 2000 meters
 

 

 

 

 

 

 

 

 

 

 

SAFETY & EMC

(Note 4)

SAFETY STANDARDS UL62368-1, UL508, TUV BS EN/EN61558-2-16, BS EN/EN61558-1, IEC62368-1, EAC TP TC 004, BSMI CNS14336-1,

IS13252(Part1)/IEC60950-1 approved; Design refer to BS EN/EN62368-1

WITHSTAND VOLTAGE I/P-O/P:4KVAC
ISOLATION RESISTANCE I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
 

 

 

EMC EMISSION

Parameter Standard Test Level / Note
Conducted BS EN/EN55032(CISPR32), CNS13438 Class B
Radiated BS EN/EN55032(CISPR32), CNS13438 Class B
Harmonic Current BS EN/EN61000-3-2 Class A
Voltage Flicker BS EN/EN61000-3-3 ——-
 

 

 

 

 

 

EMC IMMUNITY

BS EN/EN55035, BS EN/EN61000-6-2, BS EN/EN61204-3
Parameter Standard Test Level /Note
ESD BS EN/EN61000-4-2 Level 3, 8KV air; Level 2, 4KV contact, criteria A
Radiated Susceptibility BS EN/EN61000-4-3 Level 3, criteria A
EFT/Burest BS EN/EN61000-4-4 Level 3, criteria A
Surge BS EN/EN61000-4-5 Level 4,2KV/L-N, criteria A
Conducted BS EN/EN61000-4-6 Level 3, criteria A
Magnetic Field BS EN/EN61000-4-8 Level 4, criteria A
Voltage Dips and interruptions BS EN/EN61000-4-11 >95% dip 0.5 periods, 30% dip 25 periods,

>95% interruptions 250 periods

 

OTHERS

MTBF 3524.8K hrs min.     Telcordia SR-332 (Bellcore) ; 927.6K hrs min.      MIL-HDBK-217F (25℃)
DIMENSION 52.5*90*54.5mm (W*H*D)
PACKING 190g;60pcs/13Kg/0.91CUFT
 

 

 

 

 

NOTE

1.  All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.

2.  Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1μf & 47μf parallel capacitor.

3.  Tolerance : includes set up tolerance, line regulation and load regulation.

4.  The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMl testing of component power supplies.”

(as available on http://www.meanwell.com)

5.  The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft}.