Feature
- Protections: Short circuit / Overload/ Over voltage / Over temperature
- Cooling by free air convection
- Low profile:31mm
- Conformal coated
- LED indicator for power on
- Low cost, high power reliability
- 100% full load burn-in test
- 2 years warranty
Application
- Industrial automation machinery
- Industrial control system
- Mechanical and electrical equipment
- Electronic instruments, equipment
- or apparatus
- Test and measurement instrument
- Laser related machine
- Charging related equipment
- DC centralized bus(Lighting)
Specification
MODEL | HSN-300-4.2A | HSN-300-4.2B | HSN-300-5A | HSN-300-5B | |
OUTPUT |
DC VOLTAGE | 4.2V | 4.2V | 5V | 5V |
RATED CURRENT Note.2 | 50A | 60A | 50A | 60A | |
CURRENT RANGE | 0 ~ 50A | 0 ~ 60A | 0 ~ 50A | 0 ~ 60A | |
RATED POWER(convection) | 210W | 252W | 250W | 300W | |
RIPPLE & NOISE (max.) Note.3 | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | |
VOLTAGE ADJ. RANGE | 3.6~4.4V | 3.6~4.4V | 4.5~5.5V | 4.5~5.5V | |
VOLTAGE TOLERANCE Note.4 | ±3.0% | ±3.0% | ±3.0% | ±3.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION | ±2.0% | ±2.0% | ±2.0% | ±2.0% | |
SETUP, RISE TIME | 2500ms, 100ms/230VAC; 2500ms, 100ms/115VAC | ||||
HOLD UP TIME (Typ.) | 10ms/230VAC; 8ms/115VAC at full load | ||||
INPUT |
VOLTAGE RANGE | 90~132VAC or 254~373VDC | 180~264VAC or 254~373VDC | 90~132VAC or 254~373VDC | 180~264VAC or 254~373VDC |
FREQUENCY RANGE | 47 ~ 63Hz | ||||
EFFICIENCY (Typ.) | 85% | 86% | |||
AC CURRENT (Typ.) | 3.0A/230VAC; 5.0A/115VAC | ||||
INRUSH CURRENT (Typ.) | Cold start 90A/230VAC | ||||
LEAKAGE CURRENT | <1mA | ||||
PROTECTION |
OVERLOAD | A Type:105~170% rated output power B Type:105~140% rated output power | |||
Protection type : Hiccup mode, recovers automatically after fault condition is removed | |||||
SHORT CIRCUIT | Protection type : Hiccup mode, recovers automatically after fault condition is removed | ||||
OVER VOLTAGE | 4.7 ~ 5.7V | 5.7 ~ 7.0V | |||
Protection type : Hiccup mode, recovers automatically after fault condition is removed | |||||
OVER TEMPERATURE | Protection type : Shut down O/P voltage, recovers automatically after temperature goes down | ||||
ENVIRONMENT |
WORKING TEMP. | -20 ~ +70℃(Refer to “Derating Curve”) | |||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | ||||
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH | ||||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 60℃) | ||||
VIBRATION | 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes | ||||
SAFETY & EMC (Note 5) |
SAFETY STANDARDS | UL60950-1, EAC TP TC 004 approved | |||
WITHSTAND VOLTAGE | I/P-O/P:3.0KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | ||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC/25℃/ 70%RH | ||||
EMC EMISSION | Refer to EN55022 (CISPR22) Class A, EAC TP TC 020 | ||||
EMC IMMUNITY | Refer to EN61000-4-5; light industry level (surge 4KV), EAC TP TC 020 | ||||
OTHERS |
MTBF | 1758.2K hrs min. Telcordia SR-332(Bellcore) ; 226.5K hrs min. MIL-HDBK-217F (25℃) | |||
DIMENSION | 210*81*31mm (L*W*H) | ||||
PACKING | 0.67kg; 20pcs/14.4kg/0.91CUFT | ||||
NOTE |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Please refer tostatic characteristics”. 3. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 4. Tolerance : line regulation and load regulation. 5. Derating may be needed under low input voltages. Please check the static characteristics for more details. 6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
|