Switching Power Supply 60 amp 50a HSN-300 series 300W Single Output

This Switching Power Supply 60 amp is a power conversion device used to convert electrical energy from one form to another. It is a common power supply method and is widely used in various electronic devices and circuits.

Contact us

Feature

  • Protections: Short circuit / Overload/ Over voltage / Over temperature
  • Cooling by free air convection
  • Low profile:31mm
  • Conformal coated
  • LED indicator for power on
  • Low cost, high power reliability
  • 100% full load burn-in test
  • 2 years warranty

 

 

Application

  • Industrial automation machinery
  • Industrial control system
  • Mechanical and electrical equipment
  • Electronic instruments, equipment
  • or apparatus
  • Test and measurement instrument
  • Laser related machine
  • Charging related equipment
  • DC centralized bus(Lighting)

Specification

MODEL HSN-300-4.2A HSN-300-4.2B HSN-300-5A HSN-300-5B
 

 

 

OUTPUT

DC VOLTAGE 4.2V 4.2V 5V 5V
RATED CURRENT                                               Note.2 50A 60A 50A 60A
CURRENT RANGE 0 ~ 50A 0 ~ 60A 0 ~ 50A 0 ~ 60A
RATED POWER(convection) 210W 252W 250W 300W
RIPPLE & NOISE (max.) Note.3 150mVp-p 150mVp-p 150mVp-p 150mVp-p
VOLTAGE ADJ. RANGE 3.6~4.4V 3.6~4.4V 4.5~5.5V 4.5~5.5V
VOLTAGE TOLERANCE Note.4 ±3.0% ±3.0% ±3.0% ±3.0%
LINE REGULATION ±0.5% ±0.5% ±0.5% ±0.5%
LOAD REGULATION ±2.0% ±2.0% ±2.0% ±2.0%
SETUP, RISE TIME 2500ms, 100ms/230VAC; 2500ms, 100ms/115VAC
HOLD UP TIME (Typ.) 10ms/230VAC; 8ms/115VAC at full load
 

 

INPUT

VOLTAGE RANGE 90~132VAC or 254~373VDC 180~264VAC or 254~373VDC 90~132VAC or 254~373VDC 180~264VAC or 254~373VDC
FREQUENCY RANGE 47 ~ 63Hz
EFFICIENCY (Typ.) 85% 86%
AC CURRENT (Typ.) 3.0A/230VAC; 5.0A/115VAC
INRUSH CURRENT (Typ.) Cold start 90A/230VAC
LEAKAGE CURRENT <1mA
 

 

PROTECTION

OVERLOAD A Type:105~170% rated output power          B Type:105~140% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
SHORT CIRCUIT Protection type : Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE 4.7 ~ 5.7V 5.7 ~ 7.0V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
OVER TEMPERATURE Protection type : Shut down O/P voltage, recovers automatically after temperature goes down
 

 

ENVIRONMENT

WORKING TEMP. -20 ~ +70℃(Refer to “Derating Curve”)
WORKING HUMIDITY 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT ±0.03%/℃ (0 ~ 60℃)
VIBRATION 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes
 

SAFETY & EMC

(Note 5)

SAFETY STANDARDS UL60950-1, EAC TP TC 004 approved
WITHSTAND VOLTAGE I/P-O/P:3.0KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC/25℃/ 70%RH
EMC EMISSION Refer to EN55022 (CISPR22) Class A, EAC TP TC 020
EMC IMMUNITY Refer to EN61000-4-5; light industry level (surge 4KV), EAC TP TC 020
 

OTHERS

MTBF 1758.2K hrs min.       Telcordia SR-332(Bellcore) ; 226.5K hrs min.       MIL-HDBK-217F (25℃)
DIMENSION 210*81*31mm (L*W*H)
PACKING 0.67kg; 20pcs/14.4kg/0.91CUFT
 

NOTE

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.

2. Please refer to”static characteristics”.

3. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

4. Tolerance : line regulation and load regulation.

5. Derating may be needed under low input voltages. Please check the static characteristics for more details.

6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets

EMC directives.