Feature
- Ambient temperature 85°C
- High impulse withstand voltage, 10 kV
- Contact gap ≥4.0 mm (Applied to VDE0126)
- Low initial contact resistance ≤0.2 mΩ
- Rises in board temperatures are suppressed
by a low heat generation and high dissipation structure.
Specification
Item Model | Standard model | High-capacity model | |
Contact resistance *1 | 0.2 mÙ max. | ||
Operate time *2 | 30 ms max. | ||
Release time *2 | 10 ms max. | ||
Insulation resistance *3 | 1,000 MÙ min. | ||
Dielectric strength |
Between coil and contacts | 5,000 VAC, 50/60 Hz for 1 min | |
Between contacts of the same polarity | 2,000 VAC, 50/60 Hz for 1 min | ||
Impulse withstand voltage | Between coil and contacts | 10 kV (1.2 × 50 ms) | |
Vibration resistance | Destruction | 10 to 55 to 10 Hz, 0.5 mm single amplitude (1.0 mm double amplitude) | |
Malfunction | Excitation: 10 to 55 to 10 Hz, 0.5 mm single amplitude (1.0 mm double amplitude) | ||
Shock resistance |
Destruction | 1,000 m/s2 | |
Malfunction | Excitation: 100 m/s2 | ||
Durability |
Mechanical | 100,000 operations min. (at 7,200 operations/h) | |
Electrical (Resistive) *4 |
800 VAC making 50 A, carrying 200 A,
breaking 50 A; 30,000 operations min. 800 VAC making 150 A, carrying 200 A, breaking 200 A; 10 operations min. 200 A at 60 VDC; 2,000 operations min. (Switching frequency: 1 second ON – 9 seconds OFF at 85°C) |
1,000 VAC making 50 A, carrying 300 A,
breaking 50 A; 30,000 operations min. 1,000 VAC making 150 A, carrying 300 A, breaking 300 A; 10 operations min.
(Switching frequency: 1 second ON – 9 seconds OFF at 85°C) |
|
Failure rate (M level) (Reference value) *5 | 1 A at 5 VDC | ||
Use conditions |
Coil holding voltage *6 | 45% to 60% of rated coil voltage | |
Ambient operating temperature | -40°C to +85°C (with no icing or condensation) | ||
Ambient operating humidity | 5% to 85% | ||
Weight | Approx. 220 g | Approx. 235 g |
Note. The values given above are initial values at 23°C. (Except Electrical Durability)
*1. Measurement conditions: 200 A at 6 VDC (after 30 minutes) voltage drop method.
*2. Measurement conditions: Applied rated coil voltage, no contact bouncing.
*3. Measurement conditions: Measured with a 1,000 VDC megohmmeter at the same point as the dielectric strength was measured.
*4. This specification is when diode and zener diode are used. For relay coil, please connect diode and zener diode.
For more detail, please refer to lDiode Connection for Operating Coil on page 6.
*5. The value was measured at a switching frequency of 180 operations/ minute.
*6. For the detail regarding holding voltage usage, please refer to lCoil Voltage Reduction (holding voltage) after Relay Operation on page 6.