JY1000-C2-LZ Insulation Monitoring Relay

JY1000-C2-LZ is based on MODBUS protocol of DC insulation monitoring device, is used in on-line monitoring insulation resistance of the DC floating system (two DC system shared one ground). two DC channels are controlled independently, two DC insulation monitoring non-interference in each other. Users can enable or disable the insulation monitoring function of each DC channel and acquire insulation resistance values by RS485 communication.

Contact us

FEATURES

  • Two independent control
  • Remote monitoring and management
  • Monitor positive and negative poles
  • Ground insulation resistance
  • DC voltage monitoring
  • Vehicle side DC voltage monitoring
  • Voltage reverse polarity alarm

APPLICATIONS

  • Guarantee the safety and stability of charging
  • Improvement of the efficiency and charging quality
  • Personnel and equipment security
  • Electric vehicle safety testing

Specification

 

Parameter Value
Power supply 9-30VDC, Power 6W
DC voltage range 100V~1000V
DC voltage

measurement accuracy

≤2V+0.3%
Insulation resistance

measurement range

1KΩ~10 MΩ

(DC System voltage:100V~1000V)

Insulation monitoring accuracy

((When :DC voltage:100V-1000V)

CY range Resistance range Accuracy
0~0.8μF ≤60kΩ ≤3kΩ
60kΩ<R≤1MΩ ≤5%
0.8μF ~3μF ≤60kΩ ≤6kΩ
60kΩ<R≤1MΩ ≤20%
Off-line pressure test <2mA
Standard IEC 61851-23 (2014-03):2014-11
Humidity 85%
Storage temperature – 40°C ~125°C
Operating temperature – 40°C ~75°C