FEATURES
- Two independent control
- Remote monitoring and management
- Monitor positive and negative poles
- Ground insulation resistance
- DC voltage monitoring
- Vehicle side DC voltage monitoring
- Voltage reverse polarity alarm
APPLICATIONS
- Guarantee the safety and stability of charging
- Improvement of the efficiency and charging quality
- Personnel and equipment security
- Electric vehicle safety testing
Specification
Parameter | Value | ||
Power supply | 9-30VDC, Power 6W | ||
DC voltage range | 100V~1000V | ||
DC voltage
measurement accuracy |
≤2V+0.3% | ||
Insulation resistance
measurement range |
1KΩ~10 MΩ
(DC System voltage:100V~1000V) |
||
Insulation monitoring accuracy
((When :DC voltage:100V-1000V) |
CY range | Resistance range | Accuracy |
0~0.8μF | ≤60kΩ | ≤3kΩ | |
60kΩ<R≤1MΩ | ≤5% | ||
0.8μF ~3μF | ≤60kΩ | ≤6kΩ | |
60kΩ<R≤1MΩ | ≤20% | ||
Off-line pressure test | <2mA | ||
Standard | IEC 61851-23 (2014-03):2014-11 | ||
Humidity | 85% | ||
Storage temperature | – 40°C ~125°C | ||
Operating temperature | – 40°C ~75°C |