FEATURES
- Monitor the positive and negative insulation resistance separately;
- Monitor the total insulation resistance;
- report the location of the battery insulation fault;
- Automatically adapt to existing system Y capacitor CY (CY ≤4μF);
- High internal resistance up to 10MOeInjected signal amplitude ±15V;
- Fault response time ≤5s;
- High and low voltage side isolation voltage 3500 VD.C./2500 Vac.(rms);
- With CAN Bootloader, upgrade program by CAN.
APPLICATIONS
- Monitor the insulation state;
- DC floating system (IT system);
- Measuring battery pack DC voltage;
- Continuous measurement of insulation resistance of 0~50MΩ;
- Using the CAN bus interface.
Specification
Parameters | Value |
Power supply | 9~36VDC |
Input power | ≤ 2W |
Standard | IEC 61851-23 (2014-03):2014-11 |
DC voltage range | 0V~1000V |
DC voltage at pile side accuracy | ≤2V+0.3% |
Vehicle side voltage
measurement range |
0V~1000V |
Insulation resistance
measurement range |
0~50MΩ |
Insulation monitoring accuracy | ±10 % |
Bus voltage measurement accuracy | 1 % |
Insulation resistance
measurement accuracy |
0~100 KΩ, CY≤ 2μF, Bus voltage stability: ±12 KΩ
100 kΩ~1 MΩ, CY≤ 2μF, Bus voltage stability: ±10 % 1 MΩ~50 MΩ, CY =0μF, Bus voltage stability: ±10 % |
Insulation resistance
measurement response time |
RISO≥ 500 kΩ, CY =0μF, Bus voltage stability: 4 s
RISO≥ 500 kΩ, CY =0μF, Bus voltage stability: 5 s RISO=1 MΩ, CY =1μF, Bus voltage stability: 8 s RISO=1 MΩ, CY =1μF, Bus voltage stability: 12 s |
DC equivalent internal resistance | Power on: 10.2 MΩ |
Amplitude of injection pulse signal | ±15 V |
High to low voltage
withstanding voltage |
3 500 Vd.c. 2 500 Va.c.(rms) |
Off-line pressure test | <2mA |
Environment | Storage: – 40°C ~+85°C
Work: – 40°C ~85°C Humidity:85% |