FEATURES
- Remote monitoring and management;
- Monitor positive and negative poles;
- Ground insulation resistance;
- DC voltage monitoring;
- Vehicle side DC voltage monitoring;
- Voltage reverse polarity alarm.
APPLICATIONS
- DC capacitor discharge;
- Guarantee the safety and stability of charging;
- Improvement of the efficiency and charging quality;
- Personnel and equipment security.
Specification
Parameter | Value | |||
Power supply | 10-30VDC, Power 3w | |||
DC voltage range | 100V~1000V | |||
DC voltage
measurement accuracy |
≤2V+0.3% | |||
Insulation resistance
measurement range |
1KΩ~10MΩ
(DC System voltage:100V~1000V) |
|||
Insulation monitoring accuracy
((When :DC voltage:100V-1000V) |
CY range | Resistance range | Accuracy | |
0~0.8μF | ≤60kΩ | ≤3kΩ | ||
60kΩ<R≤1MΩ | ≤5% | |||
0.8μF ~3μF | ≤60kΩ | ≤6kΩ | ||
60kΩ<R≤1MΩ | ≤20% | |||
Insulation resistance value
update time after turning on |
After insulation monitoring is turned on, the time until the effective resistance value can be read for the first time | 0.7s~2s | ||
Insulation resistance value
update time |
Switch the insulation resistance until the module can read the switched insulation resistance value. | 0.5s~3s | ||
Insulation monitoring function switching times | 50*105 times | |||
Off-line pressure test | <2mA | |||
Standard | IEC 61851-23 (2014-03):2014-11 | |||
Humidity | 85% | |||
Storage temperature | – 55°C ~90°C | |||
Operating temperature | – 40°C ~75°C |