FEATURES
- High voltage grounding switch;
- Widely power supply range
- Widely insulation monitoring range (100V~2000VDC);
- Insulation monitoring equipment self-test;
- Adaptive capacitance to ground;
- Convenient parameter setting;
- Remote monitoring and management;
- Monitor positive and negative poles;
- Ground insulation resistance;
- Voltage reverse polarity alarm.
APPLICATIONS
- Insulation resistance monitoring;
- DC voltage monitoring;
- Guarantee the safety and stability of charging;
- Improvement of the efficiency and charging quality;
- Personnel and equipment security.
Specification
Parameter | Value | ||
Power supply | 10-30VDC | ||
Power supply capacity | 12V: 90mA
24V: 45mA |
≤ 1.5W | |
DC voltage range | 100V~2000V | ||
DC voltage
measurement accuracy |
0-200VDC | ≤2V | |
200~2000VDC | ≤0.5% | ||
Insulation resistance
measurement range |
1KΩ~10MΩ
(DC System voltage:100V~2000V) |
||
Insulation monitoring accuracy
((When :DC voltage:100V-2000V) |
DC voltage: 100V~300V | ≤3kΩ+10% | |
DC voltage: 300V~2000V | ≤3kΩ+5% | ||
CY range >0.3μF, Insulation resistance>1MΩ or CY range >1μF, | >10% | ||
Insulation resistance value
update time after turning on |
After insulation monitoring is turned on, the time until the effective resistance value can be read for the first time | 0.7s~2s | |
Insulation resistance value
update time |
Switch the insulation resistance until the module can read the switched insulation resistance value. | 0.5s~3s | |
Alarm relay
maximum switching voltage |
250VAC/30VDC | ||
Alarm relay
maximum switching current |
3A | ||
Alarm relay contact resistance | <100mΩ | ||
Alarm relay insulation resistance | 100MΩ | ||
Off-line pressure test | <2mA | ||
Standard | IEC 61851-23 (2014-03):2014-11 | ||
Humidity | 85% | ||
Storage temperature | – 55°C ~90°C | ||
Operating temperature | – 40°C ~75°C |