Feature
- Soft-start current can reduce the AC input impact effectively
- With short-circuit and overload protection
- 100% full-load burn-in test
- Installed with EMI filter, minimum wave
Specification
Model | LRS-150-12 | |
OUTPUT | DC VOLTAGE | 12V |
RATED CURRENT | 12.5A | |
CURRENT RANGE | 0 ~ 12.5A | |
RATED POWER | 150W | |
RIPPLE&NOISE(Max) | 150mVp-p | |
VOLTAGE ADJ.RANGE | 10.5~ 13.8V | |
VOLTAGE TOLERANCE | ±1.0% | |
LINE REGULATION | ±0.5% | |
LOAD REGULATION | ±0.5% | |
SETUP,RISE TIME | 500ms, 30ms/230VAC500ms, 30ms/115VAC(full load) | |
HOLD UP TIME(Typ.) | 40ms/230VAC35ms/115VAC (fullload) | |
INPUT | VOLTAGE RANGE | 85 ~ 132VAC/170 ~ 264VACselected by switch240~370VDC(switch on 230VAC) |
FREQUENCY RANGE | 47~63Hz | |
EFFICIENCY(Typ.) | 0.9 | |
AC CURRENT(Typ.) | 1.9A/115VAC 1.2A/230VAC | |
INRUSH CURRENT(Typ.) | COLD START 65A/230VAC | |
LEAKAGE CURRENT | <0.75mA/240VAC | |
PROTECTION | OVER LOAD |
110~150% rated output power |
Protectiontype:Hiccup mode,recoversautomaticallyafterfaultconditionisremoved | ||
OVER VOLTAGE |
28.8~33.6V | |
Protection type:Shut down o/p voltage, re-power on to recover | ||
ENVIRONMENT | WORKING TEMP | -20~70℃(Refer to “derating curve”) |
WORKING HUMIDITY | 20~90%RH non-condensing | |
STORAGETEMP.,HUMIDITY | -45 ~ +85°C, 20% ~ 95% RH non-condensing | |
TEMP.COEFFICIENT | ±0.03%/°C (0 ~ 50°C) | |
VIBRATION | 10 ~ 500Hz, 2G10min/1cycle,60min.eachX、Y、Zaxes | |
SAFETY | SAFETY STANDARDS | GB4943.1, EN60950.1APPROVED |
WITHSTAND VOLTAGE | I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | |
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100MOhms / 500VDC / 25°C/ 70% RH | |
EMC EMISSION | Compliance toEN61000-3-2:2014/EN61000-3-3:2013 | |
EMC IMMUNITY | Compliance toEN55032:2015/EN55035:2017/60950-1 | |
OTHERS | MTBF | ≥763.6K hrs MIL-HDBK-217F(25°C) |
DIMENSION | 134*97*30mm (L*W*H) |