LRS-150-12 Small Switching Power Supply

Contact us

Feature

  • Soft-start current can reduce the AC input impact effectively
  • With short-circuit and overload protection
  • 100% full-load burn-in test
  • Installed with EMI filter, minimum wave

 

Specification

Model LRS-150-12
OUTPUT DC VOLTAGE 12V
RATED CURRENT 12.5A
CURRENT RANGE 0 ~ 12.5A
RATED POWER 150W
RIPPLE&NOISE(Max) 150mVp-p
VOLTAGE ADJ.RANGE 10.5~ 13.8V
VOLTAGE TOLERANCE ±1.0%
LINE REGULATION ±0.5%
LOAD REGULATION ±0.5%
SETUP,RISE TIME 500ms, 30ms/230VAC500ms, 30ms/115VAC(full load)
HOLD UP TIME(Typ.) 40ms/230VAC35ms/115VAC (fullload)
INPUT VOLTAGE RANGE 85 ~ 132VAC/170 ~ 264VACselected by switch240~370VDC(switch on 230VAC)
FREQUENCY RANGE 47~63Hz
EFFICIENCY(Typ.) 0.9
AC CURRENT(Typ.) 1.9A/115VAC 1.2A/230VAC
INRUSH CURRENT(Typ.) COLD START 65A/230VAC
LEAKAGE CURRENT <0.75mA/240VAC
PROTECTION OVER
LOAD
110~150% rated output power
Protectiontype:Hiccup mode,recoversautomaticallyafterfaultconditionisremoved
OVER
VOLTAGE
28.8~33.6V
Protection type:Shut down o/p voltage, re-power on to recover
ENVIRONMENT WORKING TEMP -20~70℃(Refer to “derating curve”)
WORKING HUMIDITY 20~90%RH non-condensing
STORAGETEMP.,HUMIDITY -45 ~ +85°C, 20% ~ 95% RH non-condensing
TEMP.COEFFICIENT ±0.03%/°C (0 ~ 50°C)
VIBRATION 10 ~ 500Hz, 2G10min/1cycle,60min.eachX、Y、Zaxes
SAFETY SAFETY STANDARDS GB4943.1, EN60950.1APPROVED
WITHSTAND VOLTAGE I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100MOhms / 500VDC / 25°C/ 70% RH
EMC EMISSION Compliance toEN61000-3-2:2014/EN61000-3-3:2013
EMC IMMUNITY Compliance toEN55032:2015/EN55035:2017/60950-1
OTHERS MTBF ≥763.6K hrs MIL-HDBK-217F(25°C)
DIMENSION 134*97*30mm (L*W*H)