MODEL | LSP-160 -3.3 | LSP-160 -4.2 | LSP-160 -5 | LSP-160-12 | LSP-160-24 | LSP-160-36 | LSP-160-48 | |
OUTPUT |
DC VOLTAGE | 3.3V | 4.2V | 5V | 12V | 24V | 36V | 48V |
RATED CURRENT Note.7 |
32A | 32A | 32A | 13.5A | 6.75A | 4.5A | 3.4A | |
40A | 40A | 40A | 16.68A | 8.34A | 5.56A | 4.17A | ||
RATED POWER
(convection) Note.7 |
105.6W | 134.4W | 160W | 162W | 162W | 162W | 163.2W | |
132W | 168W | 200W | 200.16W | 200.16W | 200.16W | 200.16W | ||
RIPPLE & NOISE (max.) Note.2 | 200mVp-p | 200mVp-p | 200mVp-p | 240mVp-p | 240mVp-p | 240mVp-p | 300mVp-p | |
VOLTAGE ADJ. RANGE | 3.2~3.5V | 4~4.5V | 4.7~5.3V | 11.4~12.6V | 22.8~25.2V | 34.2~37.8V | 45.6~50.4V | |
VOLTAGE ADJ. RANGE for 200W | 3.2~3.3V | 4~4.2V | 4.7~5V | 11.4~12V | 22.8~24V | 34.2~36V | 45.6~48V | |
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±2.0% | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.3% | ±0.3% | ±0.3% | ±0.3% | |
LOAD REGULATION |
±1.0% | ±1.0% | ±1.0% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
|
±2.0%@40A Load | ||||||||
SETUP, RISE TIME | 2000ms, 110ms/230VAC 3000ms, 110ms/115VAC at full load | |||||||
HOLD UP TIME (Typ.) | 8ms/230Vac 8ms/115VAC | |||||||
INPUT |
VOLTAGE RANGE Note.4 | 100 ~ 264VAC 141 ~ 370VDC | ||||||
FREQUENCY RANGE | 47 ~ 63Hz | |||||||
POWER FACTOR (Typ.) | PF≥0.94/230VAC PF≥0.98/115VAC at full load | |||||||
EFFICIENCY (Typ.) | 87.5% | 87.5% | 89.5% | 92.5% | 93.5% | 93.5% | 93.5% | |
AC CURRENT (Typ.) | 2.2A/115VAC 1.1A/230VAC | |||||||
INRUSH CURRENT (Typ.) | Cold start 45A/115VAC 85A/230VAC | |||||||
LEAKAGE CURRENT | <0.75mA / 240VAC | |||||||
PROTECTION |
SHORT CIRCUIT | Hiccup protection,recovers automatically after fault condition is removed | ||||||
OVER LOAD |
130 ~ 150% rated output power(based on 160W) | |||||||
Protection type : Constant current limiting,continous increase of load will be hiccup protection, recovers automatically after fault condition is removed | ||||||||
OVER VOLTAGE |
3.8~ 4.6V | 4.62 ~ 5.46V | 5.75 ~ 6.75V | 13.2 ~ 15.6V | 26.4 ~ 31.2V | 39.6 ~46.8V | 52.8 ~ 62.4V | |
Protection type :Shut down O/P voltage,re-power on to recover | ||||||||
OVER TEMPERATURE | Shut down O/P voltage, re-power on to recover after temperature goes down | |||||||
FUNCTION |
CURRENT SHARING | Please refer to the Function Manual | ||||||
DC OK SIGNAL | Contact rating(max.):15Vdc/10mA resistive load | |||||||
ENVIRONMENT |
WORKING TEMP. | -30 ~ +70℃(Refer to “Derating Curve”) | ||||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |||||||
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH non-condensing | |||||||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 50℃) | |||||||
VIBRATION | 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes | |||||||
SAFETY & EMC (Note.6) |
SAFETY STANDARDS | UL62368,TUV BS EN/EN62368, CCC GB4943, EAC TP TC 004, BSMI CNS14336-1 approved, Design refer to BS EN/EN60335-1 | ||||||
WITHSTAND VOLTAGE | I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC | |||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG,O/P-FG:100M Ohms/500VDC/25℃/ 70%RH | |||||||
EMC EMISSION | Compliance to BS EN/EN55032,GB9254,Class B, BS EN/EN55014,BS EN/EN61000-3-2,-3,EAC TP TC 020,BSMI CNS13438 | |||||||
EMC IMMUNITY | Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11;BS EN/EN61000-6-2 (BS EN/EN50082-2),BS EN/EN55035, heavy industry level , criterial A,EAC TP TC 020 | |||||||
OTHERS |
MTBF | 699.54K hrs min. Telcordia TR/SR-332(Bellcore) ;282.71K hrs min. MIL-HDBK-217F (25℃) | ||||||
DIMENSION | 194*55*20mm (L*W*H) | |||||||
PACKING | 0.356kg;30pcs/11.68kg/0.6CUFT |