Feature
• Low power consumption due to mechanical latch for economic operation.
• Relays with mixed coil specifications can be produced (e.g., AC set coil and DC reset coil).
• Operational response fast enough to enable pulse signal power applications.
• Ambient operating temperature: –10°C to 55°C.
Specification
Item | Open or bifurcated-contact Relays |
---|---|
Contact resistance *2 | 50 mΩ max. |
Set time *3 | AC: 30 ms max.; DC: 60 ms max. (minimum pulse width for AC and DC: 100 ms) |
Reset time *3 | 30 ms max. (minimum pulse width for AC and DC: 100 ms) |
Max. operating frequency | Mechanical: 1,800 operations/hr Electrical: 1,800 operations/hr (under rated load) |
Insulation resistance *4 | 100 MΩ min. (at 500 VDC) |
Dielectric strength | 1,500 VAC, 50/60 Hz for 1 min between contacts of same polarity 2,000 VAC, 50/60 Hz for 1 min between contacts of different polarity, between contacts and coil, and between set and reset coils |
Vibration resistance | Destruction: 10 to 55 to 10 Hz, 0.375 mm single amplitude (0.75 mm double amplitude) Malfunction: 10 to 35 to 10 Hz, 0.5 mm single amplitude (1.0 mm double amplitude) |
Shock resistance | Destruction: 500 m/s2 Malfunction: 50 m/s2 |
Endurance | Mechanical: 2,500,000 operations min. (at 1,800 operations/hr) Electrical: 500,000 operations min. (at 1,800 operations/hr under rated load) *5 |
Error rate (level P) (Reference value) *6 |
10 mA at 5 VDC |
Ambient temperature | Operating: -10°C to 55°C (with no icing or condensation) |
Ambient humidity | Operating: 5% to 85% |
Weight | Standard Relays MM2K: Approx. 255 g MM3K: Approx. 390 g MM4K: Approx. 420 g MM2KP: Approx. 375 g MM3KP: Approx. 550 g MM4KP: Approx. 570 g DC-switching Relays MM2XK: Approx. 260 g MM2XK: Approx. 395 g MM4XK: Approx. 430 g MM2XKP: Approx. 380 g MM3XKP: Approx. 555 g MM4XKP: Approx. 580 g |
*1. The data shown above are initial values.
*2. The contact resistance was measured with 1 A at 5 VDC using the voltage drop method.
*3. The set or reset time was measured with the rated voltage imposed with any contact bounce ignored at an ambient
temperature of 23°C.
*4. The insulation resistance was measured with a 500-VDC megger applied to the same places as those used for
checking the dielectric strength.
*5. The electrical endurance was measured at an ambient temperature of 23°C.
*6. This value was measured at a switching frequency of 60 operations per minute.
*2. The contact resistance was measured with 1 A at 5 VDC using the voltage drop method.
*3. The set or reset time was measured with the rated voltage imposed with any contact bounce ignored at an ambient
temperature of 23°C.
*4. The insulation resistance was measured with a 500-VDC megger applied to the same places as those used for
checking the dielectric strength.
*5. The electrical endurance was measured at an ambient temperature of 23°C.
*6. This value was measured at a switching frequency of 60 operations per minute.
Characteristics (Conforming to Auxiliary Power Relay Specifications)
Vibration resistance | Destruction: 10 to 55 to 10 Hz, 0.375 mm single amplitude (0.75 mm double amplitude) Malfunction: 10 to 22 to 10 Hz, 0.5 mm single amplitude (1.0 mm double amplitude) |
---|---|
Shock resistance | Destruction: 300 m/s2 Malfunction: 30 m/s2 |
Endurance | Mechanical: 2,500,000 operations min. (at 1,800 operations/hr) Electrical: 500,000 operations min. (at 1,800 operations/hr under rated load) *2 |
Error rate (level P) (Reference value) *3 |
10 mA at 5 VDC |
Ambient temperature | Operating: -10°C to 40°C (with no icing or condensation) |
Ambient humidity | Operating: 5% to 85% |
Weight | MM4KP-JD: Approx. 570 g MM4XKP-JD: Approx. 580 g |
*1. The data shown above are initial values.
*2. The electrical endurance was measured at an ambient temperature of 23°C.
*3. This value was measured at a switching frequency of 60 operations per minute.
*2. The electrical endurance was measured at an ambient temperature of 23°C.