Fuji gas analyzers are renowned for their high accuracy and reliability in gas detection. They are widely used in various industries, including industrial production, environmental monitoring, and scientific research. Compared with other gas analyzer brands, Fuji gas analyzers have the following significant advantages:
Features of ZSVS / ZSVF Fuji Gas Analyzer
1. Portable type with built-in pump, membrane filter, and flowmeter -no need for gas sampling device
2. Multiple gas detection
It can detect multiple gases to meet the needs of different users.
3. High-precision measurement with Advanced technology
Leveraging cutting-edge sensor technology, digital signal processing, and continuously optimizing the algorithm, ZSVS / ZSVF Fuji gas analyzers deliver precise and efficient gas measurements.
4. Fast response
The response speed is fast and can monitor the changes in gas concentration in real-time.
5. A variety of functions
O2-corrected output, averaging, automatic display off, etc.
6. Excellent in long-term stability and easy maintenance using a single-beam system.
7. Strong adaptability to high temperature and high humidity environments
The Fuji electric gas analyzer can adapt to the harsh working conditions of high temperature and high humidity in the power industry.
9. Reliable data
Provides accurate and reliable gas concentration data for informed decision-making.
If the ZSVS / ZSVF Fuji Gas Analyzer does not fit you, please contact us to get other types of Fuji Electric gas analyzers, including infrared, thermal conductivity, electrochemical, laser, etc., which can meet the measurement needs of different gases and different scenarios.
Specification of ZSVS / ZSVF Fuji Gas Analyzer
Principle | CO, CO2, CH4: Non-dispersion infrared (NDIR) sensor | |
O2: galvanic sensor | ||
Measurable Components | 1 component: CO, CO2, CH4 | |
2 components: CO2 + CO, CH4 + CO, CO2 + CH4 | ||
3 components: CH4 + CO2 + CO | ||
O2 measurement can be added to above all. | ||
Measurement Range | CO: 0–200 ppm…100% | |
CO2: 0–200 ppm…100% | ||
CH4: 0–1000 ppm…100% | ||
O2: 0–5% or 0–25% | ||
Measurement range | 3 (Maximum range ratio 1 : 5) | |
Repeatability | ±0.5% FS | |
Zero drift | ≤ ±1.0% FS per day | |
Span drift | ≤ ±1.0% FS per day | |
Linearity | ±2.0% FS | |
Response time | ≤ 50 s (for 90% response) | |
O2 measurement: ≤ 3 min | ||
Output signal | 4–20 mA DC (linear) or 0–1 V DC (linear), up to 8 points, non-insulation | |
(instantaneous value, O2-corrected instantaneous value, O2-corrected average value, CP calculated value) | ||
Display | backlit LCD, English or Japanese | |
Functions | O2 correction, averaging, CP calculation, output signal hold, automatic display off | |
Communication | RS-232C (Modbus protocol) | |
Operating environment | 0–40°C, RH 90% or less | |
Power supply voltage | 100–115 V AC or 200–240 V AC, 50/60 Hz | |
Power consumption | Approx. 150 VA | |
Dimensions and weight | 365 (H) × 211 (W) × 527 (D) mm, approx. 12 kg | |
Gas conditions | Temperature | 0–40°C at inlet |
Flow rate | 0.5 L/min ±0.2 L/min per optical system | |
Dust | ≤ 10mg/Nm3 | |
Pressure | ≤ 2 kPa (gas outlet should be open to the atmospheric air) | |
Mist | Unallowable | |
Corrosive gas | HCl: ≤ 10 ppm |
Applications of ZSVS / ZSVF Fuji Gas Analyzer
- Tests for R&D such as combustion, biogas generation, and plant photosynthesis tests
- Simple measurement for control of exhaust gas from businesses place
- Control and check of CA storage atmosphere
- Combustion exhaust gas measurement control
- Comparison with gas analyzers installed at the site and backup