PRTXD Series Omega Temperature Transmitter 4 20MA

The PRTXD Series Omega Temperature Transmitter 4 20MAare two-wire transmitters that provide a 4 to 20 mA signal representing temperature. The units include a 3 1/2 digit display and the RTD sensor. The NEMA 4X (IP66) housing protects the electronics.

Units are available with 4 inch or 12 inch fixed length or spring loaded RTD probes. Spring loaded RTD probes provide good thermal contact when used in thermowells.

Contact us

Features

  • Two-Wire Transmitter
  • 4 to 20 mA Output
  • 3 1/2 Digit Display
  • RTD Probe Included, Available with 4′ or 12′ Immersion Lengths, Fixed Length or Spring Loaded for Thermomell Use

 

Applications

  • Detection, conversion and transmission of temperature in industrial automation control
  • In the field of environmental monitoring, the measurement and transmission of atmospheric temperature, water temperature, ground temperature and other parameters are realized
  • Used in weather stations, hydrological stations, geological exploration and other fields
  • In the field of medical equipment, it realizes the monitoring and transmission of patient body temperature.
  • Applied to the cold chain logistics industry to monitor and record the ambient temperature of logistics vehicles and cold storage

 

Specification

Sensor 100 W RTD element, 0.00385 alpha coefficient IEC-751 class B: ±0.3°C at 0°C, ±1.1°C at 150°C
Display 41.2 digit LCD, 1.2′ digit height, 4 readings per second, nominal display update rate
Out of Range Indication ALARM 1: On display above 200°C (392°F)

ALARM 2: On display below -50°C (-58°F)

Loop Supply Voltage Any DC supply/loop resistance that maintains 8 to 32 Vdc at gauge terminals (reverse polarity protected)
Loop Output Characteristics 4 to 20 mA output (see chart for loop voltage characteristics), minimum 8 V required at gauge terminals at all times for proper operation
Test Function Front panel TEST button when held, sets loop current and display to test calibration level, independent of temperature input to allow testing of system operation
Wiring Connections (See Drawing) 0.9 m (3′) long, 2-conductor 22 AWG cable
Operating Temperature (Electronics) -20 to 85°C (-4 to 185°F)
Storage Temperature -40 to 95°C (-40 to 203°F)
Weight Transmitter: Approx 340 g (12 oz)

Shipping Weight: Approx 450 g (1 lb)

Range -50 to 200°C (-58 to 392°F)
Resolution 0.1 degree
Accuracy ±0.1% of span plus max sensor error of ±0.3°C at 0°C or ±1.1°C at 150°C