Feature
- Universal AC input / Full range
- Built-in active PFC function, PF>0.95
- Protections: Short circuit / Over load / Over voltage
- Forced air cooling by built-in DC fan
- CH4:±Polarity is selectable
- Fixed switching frequency at 100KHz
- 3 years warranty
Application
- Industrial control system
- Mechanical and electrical equipment
- Electronic instruments
- Test and measurement instrument
- Laser related machine
- Charging related equipment
- Household appliances
- Power Sourcing Equipment of PoE
Specification
MODEL | QP-150-3A | QP-150-3B | QP-150-3C | ||||||||||
OUTPUT |
OUTPUT NUMBER | CH1 | CH2 | CH3 | CH4 | CH1 | CH2 | CH3 | CH4 | CH1 | CH2 | CH3 | CH4 |
DC VOLTAGE | 5V | 3.3V | 12V | -5V | 5V | 3.3V | 12V | -12V | 5V | 3.3V | 15V | -15V | |
RATED CURRENT | 10A | 10A | 5A | 0.6A | 10A | 10A | 5A | 0.6A | 10A | 10A | 4A | 0.6A | |
CURRENT RANGE | 3 ~ 15A | 0 ~ 15A | 0.4 ~ 5A | 0 ~ 1A | 3 ~ 15A | 0 ~ 15A | 0.4 ~ 5A | 0 ~ 1A | 3 ~ 15A | 0 ~ 15A | 0.4 ~ 5A | 0 ~ 1A | |
RATED POWER (max.) | 146W | 150.2W | 152W | ||||||||||
RIPPLE & NOISE (max.) Note.2 | 100mVp-p | 100mVp-p | 150mVp-p | 150mVp-p | 100mVp-p | 100mVp-p | 150mVp-p | 150mVp-p | 100mVp-p | 100mVp-p | 150mVp-p | 150mVp-p | |
VOLTAGE ADJ. RANGE | CH1: 4.75 ~ 5.5V CH2: 3.14 ~ 3.63V | CH1: 4.75 ~ 5.5V CH2: 3.14 ~ 3.63V | CH1: 4.75 ~ 5.5V CH2: 3.14 ~ 3.63V | ||||||||||
VOLTAGE TOLERANCE Note.3 | ±3.0% | ±3.0% | ±6.0% | ±5.0% | ±3.0% | ±3.0% | ±6.0% | ±5.0% | ±3.0% | ±3.0% | +8,-6% | ±5.0% | |
LINE REGULATION | ±1.0% | ±1.0% | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±2.0% | ±1.0% | |
LOAD REGULATION | ±2.0% | ±2.0% | ±6.0% | ±2.0% | ±2.0% | ±2.0% | ±6.0% | ±2.0% | ±2.0% | ±2.0% | ±6.0% | ±2.0% | |
SETUP, RISE TIME | 800ms, 50ms/230VAC 1800ms, 50ms/115VAC at full load | ||||||||||||
HOLD UP TIME (Typ.) | 24ms/230VAC 24ms/115VAC at full load | ||||||||||||
INPUT |
VOLTAGE RANGE | 90 ~ 264VAC 127 ~ 370VDC | |||||||||||
FREQUENCY RANGE | 47 ~ 63Hz | ||||||||||||
POWER FACTOR (Typ.) | PF>0.95/230VAC PF>0.98/115VAC at full load | ||||||||||||
EFFICIENCY (Typ.) | 73% | 75% | 74% | ||||||||||
AC CURRENT (Typ.) | 2.5A/115VAC 1.2A/230VAC | ||||||||||||
INRUSH CURRENT (Typ.) | COLD START ≦40A/230V | ||||||||||||
LEAKAGE CURRENT | <3.5mA / 240VAC | ||||||||||||
PROTECTION |
OVERLOAD |
105 ~ 150% rated output power | |||||||||||
Protection type : Hiccup mode, recovers automatically after fault condition is removed | |||||||||||||
OVER VOLTAGE |
CH1:5.75 ~ 6.75V CH2:3.8 ~ 4.4V | ||||||||||||
Protection type : Shut down o/p voltage, re-power on to recover | |||||||||||||
OVER TEMPERATURE(OPTION) | Shut down o/p voltage, recovers automatically after temperature goes down | ||||||||||||
ENVIRONMENT |
WORKING TEMP. | -10 ~ +60℃ (Refer to “Derating Curve”) | |||||||||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | ||||||||||||
STORAGE TEMP., HUMIDITY | -20 ~ +85℃, 10 ~ 95% RH non-condensing | ||||||||||||
TEMP. COEFFICIENT | ±0.03%/℃ (0~50℃) | ||||||||||||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes | ||||||||||||
SAFETY & EMC (Note 4) |
SAFETY STANDARDS | UL60950-1, TUV BS EN/EN62368-1, EAC TP TC 004 approved | |||||||||||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | ||||||||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | ||||||||||||
EMC EMISSION | Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020 | ||||||||||||
EMC IMMUNITY | Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, light industry level, EAC TP TC 020 | ||||||||||||
OTHERS |
MTBF | 1763.3K hrs min. Telcordia SR-332 (Bellcore) ; 262.6K hrs min. MIL-HDBK-217F (25℃) | |||||||||||
DIMENSION | 199*99*50mm (L*W*H) | ||||||||||||
PACKING | 0.93Kg; 20pcs/19.6Kg/1.21CUFT | ||||||||||||
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMl testing of component power supplies.” (as available on http://www.meanwell.com) 5. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft}.
|