RE22R2KMR Off Delay Timer Schneider

This Harmony RE22 modular single-function Off Delay Timer Schneider can be set between 1 second and 300 hours. It provides function K and it is mountable on DIN rail. This modular single-function timing relay is ideal for providing timing control in automation systems such as automatic door opening, alarm, lighting in toilets, and car park barriers. It has one of the market’s slimmest form factors with a 22.5mm width, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 2-pole DIN device. It also offers a sealable cover and simple and precise settings with rotary trimmers. Selectable timing range offers a one-stop solution for your power management system. Single function timer for simple integration in hard-wired logic schematics, ideal for refurbishment of old installations without using a PLC. 0 0 0 0 0 0 0 0 0 0 0 0

Contact us
Category:

Specifications

 

Complementary
Contacts type and composition 2 C/O timed contact, cadmium free
Time delay type Delay on de-energization
Time delay range 10…100 s
0.05…1 s
30…300 s
3…30 s
1…10 min
1…10 s
0.3…3 s
Control type Rotary knob
Potentiometer external
[Us] rated supply voltage 24…240 V AC/DC 50/60 Hz
Release input voltage <= 2.4 V
Voltage range 0.85…1.1 Us
Supply frequency 50…60 Hz +/- 5 %
Connections – terminals Screw terminals, 1 x 0.5…1 x 3.3 mm² (AWG 20…AWG 12) solid without cable end
Screw terminals, 2 x 0.5…2 x 2.5 mm² (AWG 20…AWG 14) solid without cable end
Screw terminals, 1 x 0.2…1 x 2.5 mm² (AWG 24…AWG 14) flexible with cable end
Screw terminals, 2 x 0.2…2 x 1.5 mm² (AWG 24…AWG 16) flexible with cable end
Tightening torque 0.6…1 N.m conforming to IEC 60947-1
Housing material Self-extinguishing
Repeat accuracy +/- 0.5 % conforming to IEC 61812-1
Temperature drift +/- 0.05 %/°C
Voltage drift +/- 0.2 %/V
Setting accuracy of time delay +/- 10 % of full scale at 25 °C conforming to IEC 61812-1
Insulation resistance 100 MOhm at 500 V DC conforming to IEC 60664-1
Recovery time 100 ms on de-energisation
Immunity to microbreaks 10 ms
Power consumption in VA 3 VA at 240 V AC
Power consumption in W 2 W at 240 V DC
Switching capacity in VA 1250 VA
Minimum switching current 10 mA at 5 V DC
Maximum switching current 5 A
Maximum switching voltage 250 V AC
Electrical durability 100000 cycles, 2 A at 24 V, DC-1
100000 cycles, 5 A at 250 V, AC-1
Mechanical durability 10000000 cycles
Rated impulse withstand voltage 5 kV for 1.2…50 µs conforming to IEC 60664-1
Power on delay 200 ms
Creepage distance 4 kV/3 conforming to IEC 60664-1
Overvoltage category III conforming to IEC 60664-1
Safety reliability data B10d = 160000
MTTFd = 171.2 years
Mounting position Any position
Mounting support 35 mm DIN rail conforming to EN/IEC 60715
Status LED LED backlight green (steady) for dial pointer indication
LED yellow (steady) for output relay energised
LED yellow (steady) for power ON
Width 22.5 mm
Net weight 0.1 kg