Meanwell RSP 100 series 100W Single Output with PFC Function

RSP 100 is a 10oW single output enclosed type AC/DC power supply.This series operates for 85~264VACinput voltage and offers the models with the DC output mostly demanded from the industry.Each modelis cooled by free air convection, working for the temperature up to 70℃.

Contact us

Feature

  • 1U Low profile with active PFC function: 75W~320W: 30 mm, 500W: 40.5 mm
  • Built-in constant current limiting circuit (RSP-75/100/150)
  • Built-in remote ON/OFF control (RSP-75/100/150/500)
  • Built-in remote sense (RSP-500 only)

 

 

Application

  • Industrial automation machinery
  • Industrial control system
  • Mechanical and electrical equipment
  • Electronic instruments, equipment
  • or apparatus
  • Test and measurement instrument
  • Laser related machine
  • Charging related equipment
  • DC centralized bus(Lighting)

Specification

MODEL RSP-100-3.3 RSP-100-5 RSP-100-7.5 RSP-100-12 RSP-100-13.5 RSP-100-15 RSP-100-24 RSP-100-27 RSP-100-48
 

 

 

 

 

OUTPUT

DC VOLTAGE 3.3V 5V 7.5V 12V 13.5V 15V 24V 27V 48V
RATED CURRENT 20A 20A 13.5A 8.5A 7.5A 6.7A 4.2A 3.8A 2.1A
CURRENT RANGE 0 ~ 20A 0 ~ 20A 0 ~ 13.5A 0 ~ 8.5A 0 ~ 7.5A 0 ~ 6.7A 0 ~ 4.2A 0 ~ 3.8A 0 ~ 2.1A
RATED POWER 66W 100W 101.25W 102W 101.25W 100.5W 100.8W 102.6W 100.8W
RIPPLE & NOISE (max.) Note.2 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 150mVp-p 150mVp-p 250mVp-p
VOLTAGE ADJ. RANGE 3.14 ~ 3.63V 4.75 ~ 5.5V 7.13 ~ 8.25V 11.4 ~ 13.2V 12.8 ~ 14.9V 14.3 ~ 16.5V 22.8 ~ 26.4V 25.7 ~ 29.7V 45.6 ~ 52.8V
VOLTAGE TOLERANCE Note.3 ±2.0% ±2.0% ±2.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
LINE REGULATION ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
LOAD REGULATION ±1.0% ±1.0% ±1.0% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
SETUP, RISE TIME 600ms, 30ms at full load
HOLD UP TIME (Typ.) 16ms at full load
 

 

 

INPUT

VOLTAGE RANGE 85 ~ 264VAC           120 ~ 370VDC
FREQUENCY RANGE 47 ~ 63Hz
POWER FACTOR (Typ.) PF>0.93/230VAC           PF>0.98/115VAC at full load
EFFICIENCY (Typ.) 83% 86% 87% 86% 86.5% 87% 87% 87% 88%
AC CURRENT (Typ.) 1.1A/115VAC          0.55A/230VAC
INRUSH CURRENT (Typ.) COLD START 30A/230VAC
LEAKAGE CURRENT <2mA / 240VAC
 

 

PROTECTION

OVERLOAD 105 ~ 135% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE 3.63 ~ 4.46V 5.5 ~ 6.75V 8.25 ~ 10.13V 13.2 ~ 16.2V 14.85 ~ 18.23V 16.5 ~ 20.25V 26.4 ~ 32.4V 29.7 ~ 36.45V 52.8 ~ 64.8V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE Shut down o/p voltage, recovers automatically after temperature goes down
FUNCTION REMOTE CONTROL CN1: < 0~0.8VDC POWER ON , 4~10VDC POWER OFF
 

 

ENVIRONMENT

WORKING TEMP. -30 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY -40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT ±0.05%/℃ (0 ~ 50℃)
VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
OVER VOLTAGE CATEGORY Ⅲ; According to EN61558, EN50178,EN60664-1, EN62477-1; altitude up to 2000 meters
 

 

SAFETY & EMC

(Note 4)

SAFETY STANDARDS UL62368-1, TUV BS EN/EN62368-1, BS EN/EN61558-1, BS EN/EN61558-2-16, EAC TP TC 004, CCC GB4943.1,

BSMI CNS14336-1 approved, Design refer to AS/NZS 62368.1

WITHSTAND VOLTAGE I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020, CNS13438, GB9254 Class B, GB17625.1
EMC IMMUNITY Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, light industry level, EAC TP TC 020
 

OTHERS

MTBF 2325.2K hrs min.       Telcordia SR-332 (Bellcore) ; 288.5K hrs min.       MIL-HDBK-217F (25℃)
DIMENSION 179*99*30mm (L*W*H)
PACKING 0.52Kg; 24pcs/14.5Kg/0.81CUFT
 

 

 

NOTE

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance : includes set up tolerance, line regulation and load regulation.

4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that

it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”

(as available on http://www.meanwell.com)

5. Strongly recommended that external output capacitance should not exceed 5000uF.(Only for: RSP-100-3.3/-5/-7.5)

6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher

than 2000m(6500ft).