Feature
- 1U Low profile with active PFC function: 75W~320W: 30 mm, 500W: 40.5 mm
- Built-in constant current limiting circuit (RSP-75/100/150)
- Built-in remote ON/OFF control (RSP-75/100/150/500)
- Built-in remote sense (RSP-500 only)
Application
- Industrial control system
- Mechanical and electrical equipment
- Electronic instruments
- Test and measurement instrument
- Laser related machine
- Charging related equipment
- Household appliances
- Power Sourcing Equipment of PoE
Specification
MODEL | RSP-500-3.3 | RSP-500-4 | RSP-500-5 | RSP-500-12 | RSP-500-15 | RSP-500-24 | RSP-500-27 | RSP-500-48 | |
OUTPUT |
DC VOLTAGE | 3.3V | 4V | 5V | 12V | 15V | 24V | 27V | 48V |
RATED CURRENT | 90A | 90A | 90A | 41.7A | 33.4A | 21A | 18.6A | 10.5A | |
CURRENT RANGE | 0 ~ 90A | 0 ~ 90A | 0 ~ 90A | 0 ~ 41.7A | 0 ~ 33.4A | 0 ~ 21A | 0 ~ 18.6A | 0 ~ 10.5A | |
RATED POWER | 297W | 360W | 450W | 500.4W | 501W | 504W | 502.2W | 504W | |
RIPPLE & NOISE (max.) Note.2 | 120mVp-p | 120mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | |
VOLTAGE ADJ. RANGE | 2.8 ~ 3.6V | 3.6 ~ 4.3V | 4.5 ~ 5.5V | 10 ~ 13.2V | 13.5 ~ 18V | 20 ~ 26.4V | 26 ~ 30V | 41 ~ 56V | |
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±2.0% | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.3% | ±0.3% | ±0.2% | ±0.2% | ±0.2% | |
LOAD REGULATION | ±1.0% | ±1.0% | ±1.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
SETUP, RISE TIME | 1500ms, 80ms/230VAC 3000ms, 80ms/115VAC at full load | ||||||||
HOLD UP TIME (Typ.) | 18ms/230VAC 14ms/115VAC at full load | ||||||||
INPUT |
VOLTAGE RANGE Note.4 | 85 ~ 264VAC 120 ~ 370VDC | |||||||
FREQUENCY RANGE | 47 ~ 63Hz | ||||||||
POWER FACTOR (Typ.) | PF>0.95/230VAC PF>0.98/115VAC at full load | ||||||||
EFFICIENCY (Typ.) | 81% | 83% | 84% | 88% | 88% | 89% | 89.5% | 90.5% | |
AC CURRENT (Typ.) | 4.2A/115VAC 2.1 A/230VAC | 5.3A/115VAC 2.65 A/230VAC | |||||||
INRUSH CURRENT (Typ.) | 20A/115VAC 40A/230VAC | ||||||||
LEAKAGE CURRENT | <2mA / 240VAC | ||||||||
PROTECTION |
OVERLOAD | 105 ~ 130% rated output power | |||||||
Protection type : Constant current limiting, recovers automatically after fault condition is removed | |||||||||
OVER VOLTAGE | 3.8 ~ 4.5V | 4.5 ~ 5.3V | 5.75 ~ 6.75V | 13.8 ~ 16.2V | 18.8 ~ 21.8V | 27.6 ~ 32.4V | 32.9 ~ 38.3V | 58.4 ~ 68V | |
Protection type : Shut down o/p voltage, re-power on to recover | |||||||||
OVER TEMPERATURE | Shut down o/p voltage, recovers automatically after temperature goes down | ||||||||
FUNCTION |
REMOTE CONTROL |
POWER ON:open or 0~0.8VDC between RC+(Pin 4)&RC-(Pin3) on CN100 POWER OFF: 4~10VDC between RC+(Pin 4)&RC-(Pin3) on CN100 | |||||||
REMOTE SENSE | Compensate voltage drop on the load wiring up to 0.3V | ||||||||
FAN CONTROL (Typ.) | RTH2≧50℃±10℃ Fan on ; RTH2≦40℃±10℃ Fan off (Fan always on for 3.3~5V,Fan ON/OFF control for 12~48V) | ||||||||
ENVIRONMENT |
WORKING TEMP. | -30 ~ +70℃ (Refer to “Derating Curve”) | |||||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | ||||||||
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH | ||||||||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 50℃) | ||||||||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes | ||||||||
SAFETY & EMC (Note.4) |
SAFETY STANDARDS | UL62368-1, TUV BS EN/EN62368-1, AS/NZS 62368.1, EAC TP TC 004 , CCC GB4943.1 , BSMI CNS14336-1approved | |||||||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | ||||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃ / 70% RH | ||||||||
EMC EMISSION | Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020,GB/T 9254, CNS13438 Class B | ||||||||
EMC IMMUNITY | Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, BS EN/EN61000-6-2, EAC TP TC 020 | ||||||||
OTHERS |
MTBF | 1372.4K hrs min. Telcordia SR-332 (Bellcore) ; 187.9K hrs min. MIL-HDBK-217F (25℃) | |||||||
DIMENSION | 230*127*40.5mm (L*W*H) | ||||||||
PACKING | 1.3Kg; 9pcs/12.7Kg/0.7CUFT | ||||||||
NOTE |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Derating may be needed under low input voltages. Please check the derating curve for more details. 5. Fan always on for 3.3~5V,Fan ON/OFF control for 12~48V. 6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) 7. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft). |