Meanwell RSP 500 series 500W Single Output with PFC Function

Contact us

Feature

  • 1U Low profile with active PFC function: 75W~320W: 30 mm, 500W: 40.5 mm
  • Built-in constant current limiting circuit (RSP-75/100/150)
  • Built-in remote ON/OFF control (RSP-75/100/150/500)
  • Built-in remote sense (RSP-500 only)

Application

  • Industrial control system
  • Mechanical and electrical equipment
  • Electronic instruments
  • Test and measurement instrument
  • Laser related machine
  • Charging related equipment
  • Household appliances
  • Power Sourcing Equipment of PoE

 

Specification

MODEL RSP-500-3.3 RSP-500-4 RSP-500-5 RSP-500-12 RSP-500-15 RSP-500-24 RSP-500-27 RSP-500-48
 

 

 

 

OUTPUT

DC VOLTAGE 3.3V 4V 5V 12V 15V 24V 27V 48V
RATED CURRENT 90A 90A 90A 41.7A 33.4A 21A 18.6A 10.5A
CURRENT RANGE 0 ~ 90A 0 ~ 90A 0 ~ 90A 0 ~ 41.7A 0 ~ 33.4A 0 ~ 21A 0 ~ 18.6A 0 ~ 10.5A
RATED POWER 297W 360W 450W 500.4W 501W 504W 502.2W 504W
RIPPLE & NOISE (max.) Note.2 120mVp-p 120mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p
VOLTAGE ADJ. RANGE 2.8 ~ 3.6V 3.6 ~ 4.3V 4.5 ~ 5.5V 10 ~ 13.2V 13.5 ~ 18V 20 ~ 26.4V 26 ~ 30V 41 ~ 56V
VOLTAGE TOLERANCE Note.3 ±2.0% ±2.0% ±2.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
LINE REGULATION ±0.5% ±0.5% ±0.5% ±0.3% ±0.3% ±0.2% ±0.2% ±0.2%
LOAD REGULATION ±1.0% ±1.0% ±1.0% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
SETUP, RISE TIME 1500ms, 80ms/230VAC            3000ms, 80ms/115VAC at full load
HOLD UP TIME (Typ.) 18ms/230VAC           14ms/115VAC at full load
 

 

 

INPUT

VOLTAGE RANGE            Note.4 85 ~ 264VAC           120 ~ 370VDC
FREQUENCY RANGE 47 ~ 63Hz
POWER FACTOR (Typ.) PF>0.95/230VAC            PF>0.98/115VAC at full load
EFFICIENCY (Typ.) 81% 83% 84% 88% 88% 89% 89.5% 90.5%
AC CURRENT (Typ.) 4.2A/115VAC         2.1 A/230VAC 5.3A/115VAC            2.65 A/230VAC
INRUSH CURRENT (Typ.) 20A/115VAC           40A/230VAC
LEAKAGE CURRENT <2mA / 240VAC
 

 

 

PROTECTION

OVERLOAD 105 ~ 130% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE 3.8 ~ 4.5V 4.5 ~ 5.3V 5.75 ~ 6.75V 13.8 ~ 16.2V 18.8 ~ 21.8V 27.6 ~ 32.4V 32.9 ~ 38.3V 58.4 ~ 68V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE Shut down o/p voltage, recovers automatically after temperature goes down
 

 

FUNCTION

 

REMOTE CONTROL

POWER ON:open or 0~0.8VDC between RC+(Pin 4)&RC-(Pin3) on CN100 POWER OFF: 4~10VDC between RC+(Pin 4)&RC-(Pin3) on CN100
REMOTE SENSE Compensate voltage drop on the load wiring up to 0.3V
FAN CONTROL (Typ.) RTH2≧50℃±10℃ Fan on ; RTH2≦40℃±10℃ Fan off (Fan always on for 3.3~5V,Fan ON/OFF control for 12~48V)
 

 

ENVIRONMENT

WORKING TEMP. -30 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT ±0.03%/℃ (0 ~ 50℃)
VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
 

SAFETY & EMC

(Note.4)

SAFETY STANDARDS UL62368-1, TUV BS EN/EN62368-1, AS/NZS 62368.1, EAC TP TC 004 , CCC GB4943.1 , BSMI CNS14336-1approved
WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃ / 70% RH
EMC EMISSION Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020,GB/T 9254, CNS13438 Class B
EMC IMMUNITY Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, BS EN/EN61000-6-2, EAC TP TC 020
 

OTHERS

MTBF 1372.4K hrs min.       Telcordia SR-332 (Bellcore) ; 187.9K hrs min.       MIL-HDBK-217F (25℃)
DIMENSION 230*127*40.5mm (L*W*H)
PACKING 1.3Kg; 9pcs/12.7Kg/0.7CUFT
 

 

 

 

NOTE

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance : includes set up tolerance, line regulation and load regulation.

4. Derating may be needed under low input voltages. Please check the derating curve for more details.

5. Fan always on for 3.3~5V,Fan ON/OFF control for 12~48V.

6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it

still meets EMC directives.For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”

(as available on http://www.meanwell.com)

7. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than

2000m(6500ft).